Blue Sea Systems 7635 m-LVD Low Voltage Disconnect User Manual

Instructions, Dc ac, Installation

Advertising
background image

CAUTION symbol refers to a potentially hazardous situation which, if not avoided, may

result in minor or moderate injury.

WARNING symbol refers to a potentially hazardous situation which, if not avoided, may

result in death or serious injury.

Instructions

PN 7635 / 7635B

Blue Sea Systems Inc.

p 360.738.8230

425 Sequoia Drive

f 360.734.4195

Bellingham, WA 98226 USA

[email protected]

www.bluesea.com

980016770 Rev.002

WARNING

CAUTION

Installation

GUARANTEE: Blue Sea Systems stands behind its products for as long

as you own them. Find detailed information at www.bluesea.com/about.

For customer service, call 800-222-7617.

Senses low battery voltage and automatically disconnects

devices to save power for starting or to preserve battery life

• Status light in both

m

-LVD and Remote Control Switch provides visual warning of low

voltage state prior to disconnect

• Alarm output available for audible warning of low voltage state

prior to disconnect (optional alarm required)

• Remote Control Switch Functions:

Disconnect Voltage Adjustment - Sets desired disconnect voltage

Override - Temporarily delays circuit disconnect for 10 minutes

OFF

- Temporarily disconnects circuits until voltage rises

Override or OFF - Silences alarm (optional alarm required)

• Includes Remote Control Switch PN 7928

DC

AC

Before beginning electrical installation, disconnect all AC and DC power sources.
Do not service equipment that has been automatically disconnected by the

m

-LVD

without first permanently removing power from the equipment by a means other

than the

m

-LVD.

WARNING

CAUTION

If you are not knowledgeable about electrical systems, consult an electrical professional.

Mount the

m

-LVD. Three mounting options are illustrated below:

1.00" (25.4mm)

SUGGESTED

MINIMUM SCREW

LENGTH

#10 SCREWS

WITH THREAD

APPROPRIATE

FOR MOUNTING

SURFACE

2-5/8" (66.7mm)

MOUNTING HOLE

DIAMETER

5/16" (7.9mm)

MAXIMUM PANEL

THICKNESS

2-5/16" (58.7mm)

MOUNTING HOLE

DIAMETER

1.00

" (25.4mm)

SUGGESTED SCREW

LENGTH FOR 1/8"

PANEL THICKNESS

#10 HEX NUTS

3/8" WIDTH

#10 MACHINE

SCREWS

2.25 (57.2mm)

SUGGESTED MINIMUM

SCREW LENGTH

#10 SCREWS

WITH THREAD

APPROPRIATE

FOR MOUNTING

SURFACE

Rear Panel Mount

Front Panel Mount

Surface Mount

Front Panel Mount (Rear View)

m

-LVD

LOW VOLTAGE DISCONNECT

Scan for
additional
product
information

1.45"

(36.83mm)

0.83"

(21.08mm)

Remote Control Switch

Mounting Hole Dimensions

Intermittent Rating: 5 min.

115A

Continuous Rating

65A

Nominal Voltage

12V DC

Cable Size

(to meet current ratings)

6 AWG (16mm²)

Terminal Stud Size

1/4"-20 (M6)

Disconnect Voltage

11.3V12.1V Adjustable

Factory Default Disconnect Voltage

12.1V

Alarm Time Before Disconnect

5 minutes

Reconnect Voltage

13V DC

Remote Control Switch

Type: SPDT, Action: (ON)-OFF-(ON)

( ) = momentary

Maximum Alarm Current

250mA

Maximum External LED Current

14mA

Regulatory

ISO 8846, Meets SAE J1171 external ignition protection requirements

Specifications

Installation

(continued)

Remove rear insulating cover as illustrated.

Advertising