The Surface Mount System panel enclosure should be installed by a

certified marine electrician.

Hazardous voltage. Improper handling can cause death or serious injury.

Turn off any shore sources and disconnect shore cord(s). Lock out other

AC power sources before beginning electrical installation.

Marine Electrical Products

SMS Surface Mount System

PN 3113 / PN 3116 / PN 3117 / PN 3118 / PN 3119 / PN 3120

Meets ABYC E11 when used with an ELCI Main circuit breaker and

mounted within 10 feet of the shore power inlet

Blue Sea Systems Inc.

p 360.738.8230

425 Sequoia Drive

f 360.734.4195

Bellingham, WA 98226 USA

[email protected]

www.bluesea.com

980009910 Rev.004

DANGER

WARNING

• Models available with ELCI Main circuit breakers for 120V 30A, 120V 50A,

and 120/240V 50A

• Blank apertures for custom breaker loading

• Glass filled polycarbonate base

• Clear cover allows easy view of circuit breaker status

• Overlapping cover for strength and increased gasket protection

• Oversized, formed in place seamless PUR gasket

• Easily removable stainless steel hinge pin for unobstructed installation

• Stainless steel latch secures cover without penetrating the enclosure

• Blank circuit positions accommodate Carling Technologies™

A and C Series Flat or Raised Rocker and ELCI Main circuit breakers

• Stainless steel mounting hardware included

• Includes waterproof glands (3116, 3117, 3118, 3119, 3120)

• LED lights for back lighting and ON indication (3116, 3117, 3118, 3119, 3120)

GUARANTEE: Blue Sea Systems stands behind its products for as long

as you own them. Find detailed information at www.bluesea.com/about.

For customer service, call 800-222-7617.

Box Specifications

Temperature Range

−40°C to +85°C

Cover Screws and Hardware

10-32, stainless steel

Mounting Hardware

¼" diameter, #12, (6 mm)

Regulatory

IP66—Protected against powerful water jets

Flammability rating—Per UL 508

Toxicity— Non-toxic, halogen free, RoHS compliant

UL Listed and NEMA 4X rated, NEMA Type 4, 4X, 6, 6P, 12, and 13

Specifications

Specifications subject to change. See www.bluesea.com for additional information and specifications

Enclosure Dimensions

4.00"

101.6mm

MOUNTING HARDWARE

CLEARANCE FOR:

Ø 1/4", #12, OR 6mm

6.65"

168.8mm

7.35"

186.8mm

4.96"

126.1mm

7.65"

194.2mm

8.13"

206.4mm

PN 3116

.63"

15.9mm

1.25"

31.8mm

Ø.49" THRU

12.5mm

Ø.89" THRU

22.5mm

Ø.80"

20.3mm

CLEARANCE

FOR LOCK NUT

Ø1.30"

33mm

CLEARANCE

FOR LOCK NUT

PG 7

CABLE

GLAND

PG 16

CABLE

GLAND

2.80"

71.1mm

1.40"

35.6mm

2X 2.08"

52.7mm 3X 1.00"

25.4mm

PN 3118, 3119, 3120

Ø.49" THRU

12.5mm

Ø1.47" THRU

37.3mm

Ø.80"

20.3mm

CLEARANCE

FOR LOCK NUT

Ø2.00"

50.8mm

CLEARANCE

FOR LOCK NUT

PG 29

CABLE

GLAND

PG 7

CABLE

GLAND

2.25"

57.2mm

1.13"

28.6mm

.60"

15.2mm

2.40"

61mm 2X

1.50"

38.1mm

1.65"

42mm

2X Ø.49"

12.5mm THRU

FOR PG 7

CABLE GLAND

2X Ø.89"

22.5mm THRU

FOR PG 16

CABLE GLAND

.43"

11mm

1.38"

35mm

Ø.80"

20.3mm

CLEARANCE

FOR LOCK NUT

Ø1.30"

33mm

CLEARANCE

FOR LOCK NUT

2.27"

57.7mm

1.38"

35mm

1.65"

42mm

.43"

11mm

2X 2.08"

52.7mm

2X 1.00"

25.4mm

.80"

20.4mm

PN 3117

Drill Guides

Advertising