Gland specifications, Installation components included – Blue Sea Systems 3119 SMS Surface Mount System User Manual

Page 2

Advertising
background image

Gland Specifications

Gland Specifications

WIRE SIZE

.230 in

5.8 mm

.530 in

13.9 mm

.114 in

2.9 mm

.250 in

6.4 mm

Min. Dia.

Max. Dia.

#6

Cable,

4 Conductor

.590 in

15.0 mm

.990 in

25.4 mm

A.

Clearance Hole

1.470 in (37.3 mm)

B.

Max. O. A. Length

2.23 in (56.6 mm)

C.

Wrenching Flats

1.66 in (42.2 mm)

Reference diagram below

A.

Clearance Hole

.886 in (22.5 mm)

B.

Max. O. A. Length

1.66 in (42.2 mm)

C.

Wrenching Flats

1.05 in (26.7 mm)

Reference diagram below

A.

Clearance Hole

.492 in (12.5 mm)

B.

Max. O. A. Length

1.17 in (29.7 mm)

C.

Wrenching Flats

.59 in (15.0 mm)

Reference diagram below

#14 to

#10

Cable,

3 Conductor

#14 to

#10

Single

Wire

CABLE DIA. RANGE DIMENSIONS

Small 3124 (PG7)

Large 3126 (PG29)

Medium 3125 (PG16)

C

B

SEALING NUT

A

SUGGESTED CLEARANCE HOLE
FOR NONTHREADED MOUNTING

Required Tools

• Hole Saw, drill or step drill suitable for cable glands (see information on back).

• Drill motor suitable for above

• Screw Drivers

• Knife

• Measuring device

• Wire cutters and Crimpers

Required Parts

• Suitable ring terminals for circuit breaker and grounding connections

• In some installations it may be desirable to attach a mounting substrate to the

hull with adhesive or epoxy instead of screwing directly to the hull.

Installing the Enclosure Panel

• The Surface Mount System Enclosure Panel should be installed by a certified

marine electrician.

• Plan the installation by determining where the enclosure will be mounted

o Per ABYC, the enclosure cannot be mounted further than the reach of a 10'

cable from the AC power inlet

o Consider the needed clearances to access the enclosure and open the sealed cover

o Allow for a wire drip loop outside the enclosure and sufficient service loop

for wires inside the enclosure

• Determine which included glands are needed. It is recommended that glands be

installed on the bottom of the enclosure to maintain the waterproof integrity of

the sealed enclosure.

• Smaller glands may permit convenient installation of a galvanic isolator if used

in the systems. In this case the line safety ground wire would exit the enclosure

to the galvanic isolator and the boat side of the galvanic isolator would return to

the enclosure to join the internal connections and the ground from the load side

power cable.

• Try all cable glands on the wire for correct fit before proceeding.

• Flat cables can be manipulated to a nearly round shape to fit and seal better

in the gland.

• Large round cables with #6 Wire may be a very tight fit in the cable gland.

Dismantle the gland and use wire lubricant to ease cable through the rubber

seal if necessary.

• When drilling holes for cable glands, be sure to allow sufficient clearance inside

for the nut. The best location is as close to the back of the enclosure as

possible and still allow for the nut.

Installation

Components Included

KEY

3113 SMS Panel Enclosure Includes:

6 blank circuit positions

6 LED plugs

12 circuit breaker mounting screws

30 Basic DC labels, 4205

30 Basic AC labels, 4206

Panel Voltage ID labels

12V DC, 24V DC

120V AC, 230V AC,

120/240V AC

3116 SMS Panel Enclosure Includes:

ELCI Main + 3 blank circuit positions

1 ELCI Main 120V 30A, 30mA, 3102

2 small wire glands, 3124

3 medium wire glands, 3125

4 green “ON” indicating 120V AC LEDs, 8034

1 red “Reverse Polarity” indicating 120V AC LED, 8066

1 LED plug

12 circuit breaker mounting screws

6 Backlit circuit label positions

1 AC Main label, 1 Reverse Polarity label, 1 ELCI label

30 Basic AC labels, 4206

Panel Voltage ID label-120V AC

3118 SMS Panel Enclosure Includes:

ELCI Main + 2 blank circuit positions

1 ELCI Main 120V 50A, 30mA, 3103

2 small wire glands, 3124

1 medium wire gland, 3125

2 large wire glands, 3126

3 green “ON” indicating 120V AC LEDs, 8034

1 red “Reverse Polarity” indicating 120V AC LED, 8066

2 LED plugs

12 circuit breaker mounting screws

5 Backlit circuit label positions

1 AC Main label, 1 Reverse Polarity label, 1 ELCI label

30 Basic AC labels, 4206

Panel Voltage ID label-120V AC

3119 SMS Panel Enclosure Includes:

ELCI Main + 1 blank circuit position

1 ELCI Main 120/240V, 50A, 30mA, 3104

2 small wire glands, 3124

1 medium wire gland, 3125

2 large wire glands, 3126

3 green “ON” indicating 120V AC LEDs, 8034

1 red “Reverse Polarity” indicating 120V AC LED, 8066

3 LED plugs

12 circuit breaker mounting screws

4 Backlit circuit label positions

1 AC Main label, 1 Reverse Polarity label, 1 ELCI label

30 Basic AC labels, 4206

Panel Voltage ID label-120V/240V AC

3117 SMS Panel Enclosure Includes:

2 x 120V AC / 30A ELCI Main

2 ELCI Main 120V 30A, 30mA, 3102

2 small wire glands, 3124

4 medium wire glands, 3125

2 green “ON” indicating 120V AC LEDs, 8034

2 red “Reverse Polarity” indicating 120V AC LEDs, 8066

2 LED plugs

12 circuit breaker mounting screws

6 Backlit circuit label positions

Source Selection Label Set (10 labels)

2 Reverse Polarity labels, 2 ELCI labels

Panel Voltage ID label-120V AC

3120 SMS Panel Enclosure Includes:

ELCI Main for Isolation Transformer

1 ELCI Main 240V, 50A, 30mA, 3093

2 small wire glands, 3124

1 medium wire gland, 3125

2 large wire glands, 3126

2 green “ON” indicating 240V AC LEDs, 6806

4 LED plugs

12 circuit breaker mounting screws

2 backlit circuit label positions

1 AC Main label, 1 ELCI label,

Panel Voltage ID Label- 240V AC

Red circuit status indicator LED
Green circuit status indicator LED
LED plug
Backlit circuit label position

Advertising