Blue Sea Systems 7611 BatteryLink Automatic Charging Relay - 12V/24V DC 120A User Manual

Batterylink, Automatic charging relay, Marine electrical products

Advertising
background image

Mounting

• To avoid corrosion to connecting wires and terminals, mount in a dry and protected location
if possible. Avoid locations directly above the battery banks.

Electrical Connections

• The wiring diagrams illustrated on the back page represent common installations and are not meant to
be a guide for wiring a specific vehicle.
• The 7611 ACR is not intended to carry starting currents. Use a battery switching system with a
combine batteries/parallel function if batteries may need to be combined for emergency starting.

Caution: Disconnect battery connections before beginning the installation.

Use the Wire Size and Fuse Ratings chart on page 2 to select the appropriate wire sizes to prevent
overheating the ACR.

Voltage Sensing

• The 7611 ACR will sense charging sources available on either battery bank.

Minimum connections for operation:

• Connect one battery bank to stud terminal

A.

• Connect the other battery bank to stud terminal

B.

• Connect the quick connect terminal marked

Ground to the DC system ground through

a ten to fifteen amp in-line fuse to prevent fault currents from flowing in this wire.

Optional connections:

1. Auxiliary Battery Priority
The 7611 ACR can be configured to allow batteries to remain “paralleled” down to a decreased
“Open Low” voltage of 12.25/24.5V DC if desired. Enable this feature if you need to access some of your
engine start battery’s stored energy for accessory loads. The feature can be configured for temporary
use while the ignition is on, or permanently. Wiring permanently allows this device to also be used as a
Low Voltage Disconnect (LVD) to prevent accidental and potentially damaging over-discharge of
accessory batteries by disconnecting loads.

To enable temporary voltage override:

• Connect a wire from the quick connect terminal marked Aux. Battery Priority through an

appropriately sized in-line fuse (1A to 10A) to a terminal or wire running from the ignition switch

that is +12/24V DC while the ignition is on, and at 0V DC when ignition is off.

To enable permanent voltage override:

• Connect a wire from the quick connect terminal marked Aux. Battery Priority through an

appropriately sized in-line fuse (1A to 10A) to a +12/24V DC source

2. Remote indicator lamp – mimics “COMBINED” LED on unit.

Appropriate 12/24V LEDs include Blue Sea Systems PNs 8033 (amber), 8171 (red), or 8172 (green).
To connect a remote LED indicator:

• Connect the red wire of the LED to a 12/24V positive source through a 2A inline fuse.
• Connect the yellow wire of the LED to the quick connect terminal marked

LED.

Open/Close Cycling

• If your electrical system is configured with a charging source that cannot supply the full load current
being drawn from the receiving batteries, an open/close cycling process can occur. If this cycling
continues, the second battery bank could eventually discharge even though a charge source
is present.

BatteryLink

®

ACR

Automatic Charging Relay

with Auxiliary Battery Priority

980011740 Rev.002

Features

• Automatically combines batteries during charging and isolates batteries when discharging
• Optional Auxiliary Battery Priority connection shares the alternator charge with the Auxiliary battery
longer allowing the use of the auxiliary loads for an extended period of time when the engine is running
• 120A Continuous rating to support high output alternators
• One tenth of the voltage drop of a battery isolator results in more fully charged batteries
• Dual sensing to manage multiple charge sources
• Robust, fully sealed assembly for reliability in environments with vibration and moisture
• Clip-on cover insulates terminal connections
• Easy to install
• Integrated LED indicates ACR status (LED is ON when batteries are combined)
• Optional remote LED output for indication of ACR status

Specifications

12V DC

24V DC

Continuous Rating

120A

120A

Intermittent Rating (5 min.)

210A

210A

Maximum Cable Size

1/0 AWG

1/0 AWG

Terminal Stud Size

3/8"-16 (M10) 3/8"-16 (M10)

Maximum Torque

140 in-lbs

140 in-lbs

Male Quick Connect Terminals 1/4

x .032

1/4

x .032

Relay Contact Position
Combine

(30 sec.)

13.6V DC

27.2V DC

Combine

(2 min.)

13.0 V DC

26.0V DC

Open Low

(30 sec.)

12.75V DC

25.5V DC

Open-Over Voltage Lockout

16.0V DC

32.0V DC

Auxiliary Battery Priority

Optional Feature
Open Low

(30 sec.)

12.25V DC

24.5V DC

Regulatory

E

marked for Ignition Protection, Meets ISO 8846,

UL 1500 and SAE J1171 external ignition
protection requirements
Rated IP67

----protected against immersion up to

1 meter for 30 minutes

Guarantee

Blue Sea Systems stands behind its products for
as long as you own them. Find detailed
information at www.bluesea.com/about.
For customer service, call 800-222-7617.

PN 7611

Marine Electrical Products

Installation Instructions

LED Status Chart

LED

Relay

Status

ON

Closed

Batteries Combined

OFF

Open

Batteries Isolated

Advertising