Recommended Installation Diagram

* This installation diagram shows a typical application only. Your application may differ.
For further information, please go to www.bluesea.com and navigate to
Resources/Application Briefs and Technical Briefs.
* Because the BatteryLink™ ACR is Dual Sensing, terminals A and B are interchangeable.
ACR function will not be affected by reversal of the starting and house batteries versus

the diagram.
* It is recommended that the ACR be connected directly to your battery positive terminals

through appropriately sized fuses. Connecting in a different location such as a battery

switch may affect accuracy because of voltage drop along current carrying conductors.
* If you are not knowledgeable about electrical systems, please consult an electrical

professional for help with installation.

LEGEND
Positive

Negative

Optional

Fuse

10A

16 AWG

start

run

accessory

off

Start Key Switch

2A

Optional

Remote LED

Auxiliary Battery Priority

Optional Connection

See Wire Size and Fuse Rating Chart for

connections of Terminals A and B.

NOTE: To determine wire sizes and fuse

ratings for all other wires illustrated

please visit the Circuit Wizard at

circuitwizard.bluesea.com

2A

16 AWG

16 AWG

Auxiliary

Battery

Start

Solenoid

Start

Battery

850 CCA* Maximum

* Cold Cranking Amperes

Dimension Drawings

Wire Size and Fuse Ratings

* Larger wire sizes may be required to minimize voltage drop in long wire runs.

For more information please use the Circuit Wizard at www.circuitwizard.bluesea.com

Wire Size and Fuse Rating Chart (Metric)

Charging Amps Minimum Wire Size* Fuse Rating

≤50

10 mm²

75-80A

≤70

16 mm²

80-90A

≤90

25 mm²

125-130A

≤110

35 mm²

150A

≤120

50 mm²

150-175A

Wire Size and Fuse Rating Chart (AWG)

Charging Amps Minimum Wire Size*

Fuse Rating

≤60

#6

75-90A

≤80

#4

100-125A

≤100

#2

150A

≤120

#1

175A