Chapter 5 - Software


This chapter will be divided into two sections. The first section

covers programming techniques for constructing a command string,
receiving data and manipulating data in QuickBASIC. The second
section discusses how to install and run the demonstration program
on an IBM PC or compatible.

Programming Techniques


This section shows steps and examples of programming the

485SDD16 in QuickBasic. If you are programming in another
language, this section can be helpful as a guideline for programming
the 485SDD16.

Read I/O Lines Command

The Read I/O Lines command returns two data bytes that

represents the states of the module's I/O lines. Refer to this
command in Chapter 3 for more information.

Step 1 - Constructing the command string:

Cmnd$ = "!" + CHR$(Maddr) + "RD"
Where Maddr is the address of the module that is to return its I/O
states.

Step 2 - Transmitting the command string:

PRINT #1, Cmnd$;

Step 3 - Receiving the data:

MSIO$ = INPUT$(1,#1)
LSIO$ = INPUT$(1,#1)

Step 4 - Manipulating the data:

MSIO = ASC(MSIO$)
LSIO = ASC(LSIO$)

Step 5 - Determining an I/O's status:

MSstatus = MSIO AND mask
LSstatus = LSIO AND mask

By "ANDing" the value of MSIO or LSIO with the appropriate
mask of an I/O line, the status of the I/O line can be determined.
If the status is equal to zero the I/O line is LOW. If the status is not
equal to zero the I/O line is HIGH. Table 5.1 shows the mask
values for each I/O line.

Step 6 - Repeat Step 5 until the status of each I/O line has been

determined.

22 485SDD16-1005

Manual

B&B Electronics -- 707 Dayton Road -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 433-5104


Example 5.1 - Determining the status of I/O lines #2 & #10 of

module #5.

Maddr = 5
mask = &H4
Cmnd$ = "!" + CHR$(Maddr) + "RD"
PRINT #1, Cmnd$;
MSIO$ = INPUT$(1,#1)
LSIO$ = INPUT$(1,#1)

MSIO = ASC(MSIO$)
LSIO = ASC(LSIO$)
MSstatus = MSIO AND mask
LSstatus = LSIO AND mask

If LSstatus equals zero then I/O line #2 is LOW. If LSstatus is not
equal to zero then I/O line #2 is HIGH. If MSstatus equals zero then
I/O line #10 is LOW. If MSstatus is not equal to zero then I/O line
#10 is HIGH.


Read Configuration Command

The Read Configuration command reads the module's I/O

definitions, Power-up states, Address, and Turn-around delay
respectively. Refer to this command in Chapter 3 for more
information.

Step 1 - Constructing the command string:

Cmnd$ = "!" + CHR$(Maddr) + "RC"
Where Maddr is the address of the module that is to return its
configuration.

Step 2 - Transmitting the command string:

PRINT #1, Cmnd$;

Table 5.1 - Digital I/O Mask Values

Mask

Values

I/O Line #

Hexadecimal

Decimal

0 & 8

1H

1

1 & 9

2H

2

2 & 10

4H

4

3 & 11

8H

8

4 & 12

10H

16

5 & 13

20H

32

6 & 14

40H

64

7 & 15

80H

128