Ez gas_reva_flippedelectrode_1, Bsize, Ezgas pro burner at-a-glance – Carlin EZGasPro User Manual

Page 3: Carlin combustion technology, inc, Model ezgas pro gas burner — instruction manual

Advertising
background image

Model EZGas Pro gas burner — Instruction manual

Carlin part number MNEZGas Rev. 10/28/13

– 3 –

Where appliance instructions differ from this manual, follow the appliance instructions.

EZGas Pro burner at-a-glance

12 Primary control (Carlin Model 60200FR microprocessor-based inter-

rupted ignition flame supervisory control, for use with flame rod flame

rectification)

13 Flame current test jack

14 Burner junction box

15 Motor (Carlin PSC motor, with permanently-lubricated bearings and

automatic thermal overload protection)

16 Blower housing (cast aluminum), with powder coat paint finish

17 Blower wheel

18 Air band with indicator — Only a single adjustment required for setting

combustion air; see page 7 for starting setting based on appliance

model and input)

19 Airflow proving switch — Prevents burner from firing if air is not moving

20 Combination gas valve (with integral gas pressure regulation — set for

3½” w.c. outlet pressure) - 24V

21 Gas supply entrance — ¾” NPT; 5” w.c. min; 14” w.c. max

22 24V Transformer

1 Air tube (flange omitted for clarity), with powder coat paint finish

2 Diffuser plate (interchangeable hole or slot pattern)

3 Gas manifold (concentric cylinders swaged at ends) — Gas manifold

delivers gas to gas openings on inner wall of manifold near the dif-

fuser plate.

4 Ignitor electrode

5 Flame rod

6 Gas orifice nipple — see pages 7 and 8 for orifice sizing requirements

7 Gas inlet connection (gas entrance to gas manifold)

8 Gas manifold outer wall

9 Gas manifold inner wall

10 Hinged cover plate (for access to blower wheel & electrodes)

11 Ignitor — Carlin Model 41800 solid state electronic ignitor — 9,000

volts, continuous duty rated)

QUALITY CHARACTERISTICS

CRITICAL

MAJOR

A

MAJOR

B

MINOR

NO

SYMBOL

CRITICAL

STATISTICAL

SEE QAS 1000 FOR VENDORS QUALITY

ASSURANCE REQUIREMENTS

TOLERANCE UNLESS OTHERWISE SHOWN

FRACTIONAL `1/64 ANGLE `1/2~

DEC. .XX `.01 .XXX `.005

THIS DOCUMENT MAY NOT BE

REPRODUCED WITHOUT WRITTEN

PERMISSION FROM CARLIN

COMBUSTION TECHNOLOGY, INC.

REMOVE BURR AND FLASH FOR

PROPER OPERATION AND GOOD

APPEARANCE

THIRD ANGLE PROJECTION

DO NOT SCALE DRAWING

INTERPRET ALL DIMENSIONS

PER ANSI Y14.5 1994

CARLIN COMBUSTION TECHNOLOGY, INC.

EAST LONGMEADOW, MA U.S.A.

PART

NUMBER

MAT'L

NUMBER

PART

DESC.

MAT'L

DESC.

ITEM

CLASS

ITEM

CLASS

ECN #

REV SH

OF

DRAWING

NUMBER

DRAWN

DATE

SCALE

EZ

GAS_RevA_FlippedElectrode_1

wmisiaszek

9/4/2013

ECN

BSIZE

ALL LINEAR DIMENSIONS

ARE IN INCHES

REVISION HISTORY

REV

DESCRIPTION

ECN

BY

DATE

.

Released to Production

ECN

MPC

5/4/2009

1

2

3

4

5

6

7

8

9

10

11

14

15

16

17

18

19

22

21

20

12

13

Advertising