Where appliance instructions differ from this manual, follow the appliance instructions.

2. Install gas piping from meter to combination gas valve

Gas supply pressure

natural or propane

• Maximum supply pressure:

14 inches w.c.

• Minimum supply pressure:

5 inches w.c.

Do not expose the combination gas valve to gas pressure

in excess of 14 inches water column. Higher pressure could
damage the valve seat, resulting in potentially hazardous
condition. When pressure testing piping at higher pressures,
disconnect burner from gas line before testing.

If the gas supply pressure can exceed 14 inches water col-
umn at any time, you must install a lockup type gas pressure
regulator in the gas supply piping, ahead of the main manual
gas valve installed at the burner.

Test and purge gas line

Read WARNING above.
Pressure test and purge the line. Pressure testing should be done by the
gas supplier or utility, following all applicable codes.

Piping from meter to burner

Connect from the gas supply to the burner combination gas
valve inlet using new, clean black iron pipe and malleable iron
fittings only. Do not use copper, brass, cast iron or galvanized
pipe or fittings.

Provide support for gas piping. Do not rest weight of piping
on burner gas valve.

Apply pipe dope sparingly at all joints. Use only pipe dope
listed for use with propane gas. Do not use pipe sealing tape.

Do not hold gas valve with pipe wrench. Use crescent wrench
or other smooth-jawed device. Do not over-tighten.

Failure to comply with above could result in severe personal
injury, death or substantial property damage.

1. If possible, install a new gas line directly from the gas meter. If you are

using an existing gas line, verify it is clean and in good condition, and
verify it is large enough to handle the load of all connected appliances.

2. When branching from a common gas line, do not tap off from the bottom

of horizontal sections — only from the side or top.

3. Install a main manual shutoff valve, sediment trap and ground joint

union near the burner combination gas valve connection as shown in
Figure 6.

4. If the burner is installed inside the appliance jacket, install the main

manual gas valve and sediment trap external to the jacket.

5. Size piping (or verify size) using Table 2. You will find additional informa-

tion on gas line sizing in the National Fuel Gas Code, ANSI Z223.1.

Figure 6 Connecting gas supply piping to burner

Table 2

Capacities of black iron pipe, cubic feet gas/hour

In the state of Massachusetts, when lever-type gas shutoffs

are used, they must be T-handle type only.

1 Pipe to meter or branch
2 Main manual gas shutoff valve
3 Use clean, burr-free black iron pipe

and malleable iron fittings

4 Ground joint union

5 Sediment leg
6 Burner combination gas valve
7 Upstream pressure tap, 1/8”
8 Outlet pressure tap, 1/8”
9 Gas regulator access screw
10 Gas valve electrical connection

QUALITY CHARACTERISTICS

CRITICAL

MAJOR

A

MAJOR

B

MINOR

NO

SYMBOL

CRITICAL

STATISTICAL

SEE QAS 1000 FOR VENDORS QUALITY

ASSURANCE REQUIREMENTS

TOLERANCE UNLESS OTHERWISE SHOWN

FRACTIONAL

`

1/64 ANGLE

`

1/2

~

DEC. .XX `

.01 .XXX

`

.005

THIS DOCUMENT MAY NOT BE

REPRODUCED WITHOUT WRITTEN

PERMISSION FROM CARLIN

COMBUSTION TECHNOLOGY, INC.

REMOVE BURR AND FLASH FOR

PROPER OPERATION AND GOOD

APPEARANCE

THIRD ANGLE PROJECTION

DO NOT SCALE DRAWING

INTERPRET ALL DIMENSIONS

PER ANSI Y14.5 1994

CARLIN COMBUSTION TECHNOLOGY, INC.

EAST LONGMEADOW, MA U.S.A.

PART

NUMBER

MAT'L

NUMBER

PART

DESC.

MAT'L

DESC.

ITEM

CLASS

ITEM

CLASS

ECN #

REV SH

OF

DRAWING

NUMBER

DRAWN

DATE

SCALE

EZ

GAS_RevA_FlippedElectrode_Main

wmisiaszek

9/4/2013

ECN

BSIZE

ALL LINEAR DIMENSIONS

ARE IN INCHES

REVISION HISTORY

REV

DESCRIPTION

ECN

BY

DATE

.

Released to Production

ECN

MPC

5/4/2009

9

7

10

8

1

2

3

4

5

6

7

Advertising