18

18

EN

3

4
5
6

7B

7A

1

2

140-145 cm

115-125 cm

1

2

3A

3B

3C

4

Art. 2608

Cannot be used for the intercom function.
The door-entry phone should always be mounted using Art. 1214/2C as
illustrated in connection diagram BK/FI on page 91.

1 Privacy function indicator.
2 3-position ringtone/Privacy service selector:

High position: Maximum ringtone volume.

Middle position: Medium ringtone volume.

Low position: Privacy function activation.

Privacy service means exclusion of the call ringtone from the external
unit and switchboard; activation of the Privacy function is signalled by
a red indicator appearing at the top right-hand side).

3 Trimmer for adjusting the microphone volume.
4 User

code programming microswitches.

5 System connection terminals:

L L Bus line connection.

CFP CFP Floor door call input.

P1 C1 Button P1 terminals for various purposes (contact C. NO 24 V -
100 mA max.) (remove CV1 and CV2, see variant SB/X3 on page 93).

S+ S- Terminals for call repetition device.

6 CV1 CV2 Jumpers to be removed in order to have potential-free C.

NO contact on button P1.

7A/7B JP1 Jumpers for selecting the switchboard call (position C) /

generic actuator (position A) function of button P1.

Description of buttons:
A Key button.
P1 Button P1 for switchboard call / generic actuator / button for various

purposes present on terminal block (P1 C1).

Clean using a damp cloth. Do not use alcohol or other aggressive
products.

Installing door-entry phone Art. 2608

Advertising