Comelit MT 8171I User Manual

Page 20

Advertising
background image

20

20

EN

S1-5

S1-4

S1-3

S1-2

S1-1

12345678

1

2

3

4

ON

5

6

7

8

DIP

1

2

3

4

ON

5

6

7

8

DIP

S1-8

S1-7

S1-6

S1-4

S1-3

S1-2

S1-1

S1-5

Description of button functions and settings

Settings for bracket Art. 5714/K and Style door-entry phone Art. 2608

Position of the microswitches for bracket Art. 5714/K and Style door-entry phone Art. 2608

The values of S1-1, S1-2, S1-3, S1-4 and S1-5 define the call address of the bracket and door-entry phones as shown in the table below.

A

P1

P2

P3

P4

P5

P6

DIP

6

DIP

7

DIP

8

S1

Default

0

0

0

A

Actuator

Internal ignition /

Video request

Switchboard call

Single-family

intercom call

Two-family

intercom call

¹

Doctor

A

Single-family

intercom call

Two-family

intercom call

¹

Switchboard call

Single-family

intercom call

Two-family

intercom call

¹

Doctor

1

0

0

A

Single-family

intercom call

Doctor

Switchboard call

Single-family

intercom call

Two-family

intercom call

¹

Doctor

0

1

0

A

Two-family

intercom call

¹

Doctor

Switchboard call

Single-family

intercom call

Two-family

intercom call

¹

Doctor

1

1

0

A

Single-family

intercom call

Internal ignition /

Video request

Switchboard call

Single-family

intercom call

Two-family

intercom call

¹

Doctor

0

0

1

A

Two-family

intercom call

¹

Internal ignition /

Video request

Switchboard call

Single-family

intercom call

Two-family

intercom call

¹

Doctor

1

0

1

A

Switchboard call

Internal ignition /

Video request

Switchboard call

Single-family

intercom call

Two-family

intercom call

¹

Doctor

0

1

1

A

Switchboard call

Actuator

Switchboard call

Single-family

intercom call

Two-family

intercom call

¹

Doctor

1

1

1

Code

S1

Code

S1

Code

S1

Code

S1

1

9

17

25

2

10

18

26

3

11

19

27

4

12

20

28

5

13

21

29

6

14

22

30

7

15

23

8

16

24

► For door-entry phones Art. 2608, Art.

2610 and Art. 2628, set dip switches
S1-6, S1-7, S1-8 to OFF

The values of S1-6, S1-7 and S1-8 define the operating mode of the Bravo Kit System, as shown in the table below.

√ ¹ The two-family intercom call function cannot be used with the single-family Bravo Kit Art. 8171I