PRODUCT DIAGNOSTICS

15

14

Connecting your Equipment
Plug the equipment into the output receptacles on the back panel of the unit. If
your UPS is a 3U rack, there are a total of eight outlets, with seven outlets
providing backup plus surge protection and one outlet for surge-only protection.
However, if your UPS is a 2U rack, there are a total of six outlets, with five
outlets providing backup plus surge protection and one outlet for surge-only
protection. Please ensure that you do not exceed the maximum output rating
(watts) of the UPS (refer to the UPS’ back panel or the Technical Specifications
section).

Note: Connecting the RS232 computer interface port to a computer is necessary to run the software but
is optional.

Note: Connecting to the computer interface port is optional. The UPS works properly without a
connection.

Note: Connecting to the telephone/network surge protection connection is optional. The UPS works
properly without a connection.

1. The computer interface port is for the UPS monitoring and control.

2. The RJ45/RJ11 modular connectors are used for 10Base-T

network/single-line telephone surge protection.

3. The output receptacles are NEMA 5-15R type. (IEC output sockets on

230VAC models)

4. The output circuit breakers will trip in the event the individual banks

of the output receptacles exceed the rating of the circuit breaker.
(Not on all models)

5. The input circuit breaker will trip in the event the load exceeds the UPS’

power rating.

6. The input power cord has a NEMA 5-15P connector. (IEC input socket on

230VAC models)

7. The DIP switch setting may be changed by the user to set the desired

inverter (on-battery) output voltage.

8. The “Surge Only” output receptacle is for surge protection only. It is not

battery backed-up.

PRODUCT INSTALLATION

CAUTION! Do not connect a laser printer to the battery backup
receptacles on the UPS unless the UPS is rated 2000VA or
greater. A laser printer draws significantly more power when
printing than at idle, and may overload the UPS.

CAUTION! RJ 45 Port Use only 26 AWG phone line.

Protect

Use only

26 AWG

Phone Line

Caution:

RS232

SW1/SW2

Output

Voltage

OFF /OFF

OFF / ON
ON /OFF

ON / ON

110/220V

110/220V

120/230V

127/240V

Circuit

Breaker

Power

Input

UPS Output

Surge Only

Protect

Use only

26 AWG

Phone Line

Caution:

RS232

SW1/SW2

Output

Voltage

OFF /OFF

OFF / ON

ON /OFF

ON / ON

110/215V

110/215V

120/225V

127/235V

Circuit

Breaker

Power

Input

UPS Output

Surge Only

(2U Rack, 120VAC models shown) (2U Rack, 230VAC models shown)

Fig. 3: Rear Panel

(3U Rack, 120VAC models shown) (3U Rack, 230VAC models shown)

Advertising