6.3. Main and Auxiliary Power

The Gold DC Whistle receives power from main and auxiliary supplies and delivers power to the
motor.

6.3.1.

Description

This section describes the Main and Auxiliary Power for power ratings 200V and 100V, and provides
details for the optional Backup (Auxiliary) Supply.

The Gold DC Whistle Power rating is 12 to 195 VDC

There are Two power ratings for Gold DC Whistle; 100V and 200V:

Power rating of 200V
Two power isolated DC power sources are required, main power 12 - 195V and Auxiliary Power
12-95V for the logic.
Power rating of 100V
Single DC Power Supply - Power to the Gold DC Whistle is provided by a 12–95 VDC single
isolated DC power source (not included with the Gold DC Whistle). A “smart” control-supply
algorithm enables the Gold DC Whistle to operate with only one power supply with no need for
an auxiliary power supply for the logic.
Optional Backup (Auxiliary) Supply
If backup functionality is required in case of power loss, e.g., to keep the original position, a
12–95 VDC external isolated supply should be connected (via the Gold DC Whistle’s VL+
terminal). This is more flexible than the requirement for 24 VDC supply.
If backup is not needed, a single power supply is used for both the power and logic circuits.
There are two voltage ratings of the Gold DC Whistle, therefore the correct power supply must
be used, according to the maximum operating voltage of the Gold DC Whistle. Refer to section
4.2 Technical Data.