Can communication version – ElmoMC Gold Line Digital Servo Drives-Gold DC Whistle User Manual
Page 57

Gold DC Whistle Installation Guide
MAN-G-DCWHIIG-EC (Ver. 1.700)
||CAN Communication Version
57
6.11. CAN Communication Version
Fieldbus communications are industrial network protocols for real-time distributed control that
allows connection of servo drives. The Gold DC Whistle supports the following CAN fieldbus type
industrial network protocol:
Fieldbus Type
Product Number
CAN
G-DCWHI XX/YYY
S
XX
See Section 12.4 in the MAN-G-Panel Mounted Drives Hardware manual for the electrical diagram.
Pin (J7, J8) Signal
Function
1
CAN_H
CAN_H bus line (dominant high)
2
CAN_L
CAN_L bus line (dominant low)
3
COMRET (CAN_RET)
CAN Return
4, 5
N/A
—
6
CAN_SHLD
Shield, connected to the RJ plug cover
7
CAN_RET
CAN Return
8
N/A
—
Pin Position
Standard CAT5e Ethernet Cable
Table 11: CAN In/Out Connectors Pin Assignments