General

Racks are available in nine configurations:

1.6m high Rear Access (RA) racks [160cm x 60cm x 80cm 170kg (excluding modules)]

o

72ch 18 modules 4x16A [7541A1714]

o

108ch 18 modules 6x16A [7541A1715]

o

72ch 15 modules 4x16A, 3 modules 4x32A* [7541A1716]

2.0m high Rear Access (RA) racks [200cm x 60cm x 80cm 215kg (excluding modules)]

o

108ch 27 modules 4x16A [7541A1717]

o

162ch 27 modules 6x16A [7541A1718]

o

162ch 21 modules 4x16A, 6 modules 4x32A* [7541A1719]

2.0m high Swing Frame (SF) racks [200cm x 80cm x 83cm 260kg (excluding modules)]

o

108ch 27 modules 4x16A [7541A1720]

o

162ch 27 modules 6x16A [7541A1721]

o

162ch 21 modules 4x16A, 6 modules 4x32A* [7541A1722]

* Modules are limited to a maximum current per module of 63A and will not provide 100% power out
for 4 x 32A simultaneous loads.

Environmental specification

Operating temperature: 0-35degC

Dimmer room HVAC systems must at all times maintain the specified ambient temperature at the
dimmer rack. Dimming systems operating within 5degC of the upper or lower temperature limits must
strictly follow installation and operation guidelines to operate reliably.

Relative humidity: 30%-90% non-condensing.

Mechanical specification

Rugged steel construction. Fine-textured scratch resistant epoxy paint. Top trunking/conduit access
through plain steel cover panel. Bottom cable access through removable panels.

Front access to processor controls and indicators and fitting/removal of dimmer modules.

Air intake through perforated rear door panel.

Each module fitted with ventilation fan with exhaust to front.

All modules and processor may be locked in place with supplied screw.

Electrical specification

Three phase 380-415 VAC Star system, line frequency 47-63Hz

Maximum current 400A per phase (600A option available)

Load terminals are 4mm

2

[12 AWG] up to 3kW, 10mm

2

up to 5kW [8 AWG] and 16mm

2

[4 AWG] up to

12kW.

50,000 AIC rack rating

All racks are CE compliant.