Introduction, How to use this guide, Warnings and notice conventions – ETC Matrix MkII Rack User Manual

Page 5: Scope of this guide

Advertising
background image

Introduction

1

Introduction

Welcome to the installation manual for Matrix® Mk.II dimmer racks. This manual contains the
procedures for safe and efficient installation of Matrix Mk.II rear access racks and swing frame racks
and includes information on electrical wiring installation and the complete dimming system checking. It
does not include programming and commissioning as these subjects are described in the relevant
ETC operational manuals.

How To Use This Guide

Use this guide during system installation. It contains complete installation instructions up to the point
of programming and commissioning. The procedures for programming and using the system are
described in the relevant ETC Operational Manuals.

When viewing this document in electronic form (PDF file) with Adobe Acrobat Reader, blue italicized
text followed by a page number such as

Positioning of Racks, page 8

, is a link within the document. If

you click on the link, the screen will display that section or topic.

Warnings and Notice Conventions

These symbols are used in Matrix Mk.II documentation to alert you to danger or important information:

Note:

Notes are helpful hints and information that is
supplemental to the main text.

CAUTION:

A Caution statement indicates situations where
there may be undefined or unwanted
consequences of an action, potential for data loss
or an equipment problem.

WARNING:

A Warning statement indicates situations where
damage may occur, people may be harmed, or
there are serious or dangerous consequences
of an action.

WARNING:

RISK OF ELECTRIC SHOCK! This warning
statement indicates situations where there is a
risk of electric shock

Scope Of This Guide

This guide explains the installation procedure for the following Matrix Mk.II racks:

Rear access racks

o

1.6m 72ch 18 modules 4x16A [7541A1714]

o

1.6m 108ch 18 modules 6x16A [7541A1715]

o

1.6m 72ch 15 modules 4x16A, 3 modules 4x32A [7541A1716]

o

1.6m 54ch 18 modules 3x32A [7541A1723]

o

2.0m 108ch 27 modules 4x16A [7541A1717]

o

2.0m 162ch 27 modules 6x16A [7541A1718]

o

2.0m 108ch 21 modules 4x16A, 6 modules 4x32A [7541A1719]

o

2.0m 81ch 27 modules 3x32A [7541A1724]

Swing frame racks (front access)

o

2.0m 108ch 27 modules 4x16A [7542A1720]

o

2.0m 162ch 27 modules 6x16A [7542A1721]

o

2.0m 108ch 21 modules 4x16A, 6 modules 4x32A [7542A1722]

o

2.0m 81ch 27 modules 3x32A [7542A1725]

Advertising