ETC Alex M Alex MX User Manual
Page 43

The menu pages
Menu page 1: Intensities
Alex M
030430-150B
Alex_M_E_150C_A5.doc
– 43 –
Input/display fields
1st row
under bar chart
Contribution made by Alex M to the output levelSpecified
in percent for each channel
Value
range:
Factory setting:
0 to FF (0% to 100%)
All 0
2nd row
under bar chart
Status display, entry for each channel
Circuit closed, no error
−
Circuit open (no lamp connected,
spotlight
defective)*
E Fuse
triggered
P Phase
error
MEM X
=
Input field for saving the current output level as a preset
X
Memory block, value range: 1 to 12
=
Memory block is assigned
ALL LEV
Input field: The same internal output level can be as-
signed to all channels.
DMX 1 CM
Indicates the signal source, which can be any of the
following:
DMX xxx CM
DMX and Memory/Chaser or
analog, DMX and Memory/Chaser
DMX xxx -
-
DMX only
ANA - - - CM
Analog and Memory/Chaser
ANA - - - - -
Analog only
- - -
- - - CM
Memory/Chaser only
xxx = DMX start address
Memory/Chaser = stored presets/chases
L1 230V
L2 230V
L3 230V
Displays the current phase voltages.
- - -
Phase missing
*) The display ”-” (Circuit open) is not available on units fitted with an
electronic base load.