Operating instructions nz.vz-...vs safety switch, Technical data – EUCHNER NZ.VZ-xxxVS User Manual

Page 7

Advertising
background image

Operating Instructions NZ.VZ-...VS Safety Switch

Technical data

Parameters

Value

Housing material

Anodized die-cast alloy

Degree of protection
acc. to IEC 60529

IP65

Mech. operating cycles

2 x 10

6

Ambient temperature

-25 °C ... +80 °C

Installation position

Any

Approach speed, max.

20 m/min

Approach speed, min.

0.02 m/min (NZ.VZ-511...)

Actuation frequency

7000 / h

Actuating force at 20 °C
(not locked)

45 N

Extraction force

40 N

Retention force

35 N

Locking force F

max

(in locked position)

2000 N

Locking force F

Zh

acc. to

(incl. safety margin acc. to GS-ET-19)
Weight

approx. 0.75 kg

Switching principle switching elements
511

Snap-action switching contact

528, 538, 2121, 2131, 3131

Slow-action switching contact

Contact material

Silver alloy, gold flashed

Connection type
NZ1VZ...

Screw terminals M20 x 1.5

NZ2VZ...

Plug connector

Conductor cross-section (rigid/flexible)
NZ1VZ...

0.34 ... 1.5 mm

2

NZ1VZ...L (with indicator LED)

max. 0.75 mm

2

Conductor cross-section mating connector
SR6 (NZ2VZ-5...)

(0.5-1.5) mm

2

SR11 (NZ2VZ-2.../NZ2VZ-3...)

0.5 mm

2

Rated insulation voltage
NZ1VZ.../NZ2VZ-5...

U

i

= 250 V

NZ2VZ-2.../NZ2VZ-3...

U

i

= 50 V

Rated impulse withstand voltage
NZ1VZ.../NZ2VZ-5...

U

imp

= 2.5 kV

NZ2VZ-2.../NZ2VZ-3...

U

imp

= 1.5 kV

Rated short-circuit current

100 A

Degree of contamination
(external, acc. ?to EN 60947-1)

3 (industrial)

Switching current, min., at 24 V
NZ.VZ-511...

10 mA

NZ.VZ-...

1 mA

Switching voltage, min., at 10 mA 12 V
Utilization category to IEC 60947-5-1
NZ.VZ-511...

AC-15 6A 230V / DC-13 6A 24V

NZ1VZ.../NZ2VZ-5...

AC-15 4A 230V / DC-13 4A 24V

NZ2VZ-2.../NZ2VZ-3...

AC-15 4A 50V / DC-13 4A 24V

Conventional thermal current I

th

NZ.VZ-511...

6 A

NZ.VZ...

4 A

Short circuit protection (control circuit fuse)
NZ.VZ-511...

6 A gG

NZ.VZ...

4 A gG

Solenoid operating voltage/solenoid power consumption
VSE03/VSM03

DC 19V/AC 24V

(+10%/-15%)

8 W

VSE04/VSM04

DC 24V

(+10%/-15%)

8 W

VSE05/VSM05

DC 41V / AC 48V (+10%/-15%)

8 W

VSE06/VSM06

DC 48V

(+10%/-15%)

8 W

VSE07/VSM07

DC 97 V/AC110 V (+10%/-15%)

8 W

VSE09/VSM09

DV 196V/AC 230V (+10%/-15%) 10 W

Solenoid duty cycle ED

100 %

Solenoid power consumption

< 10 W

Plug connector for solenoid locking
DC

Order No. 028 345

AC

Order No. 028 338

Indicator LED (only with switching element 511, 528, 538)
L060

AC/DC

12...60 V

L110

AC

110 V

(±15 %)

L220

AC

230 V

(±15 %)

Limitations at ambient temperature above +70 ... +80 °C
Utilization category
NZ2VZ-5...

AC-15 2A 230V / DC-13 2A 24V

NZ2VZ-2.../NZ2VZ-3...

AC-15 2A 50V / DC-13 2A 24V

Conventional
thermal current I

th

2 A

Short circuit protection

2 A gG

Reliability figures according to EN ISO 13849-1

B

10d

4.5 x 10

6

Figure 8: Dimension drawing NZ1VZ-...VSM/VSE with cable entry

M=1,2Nm

M=1,2Nm

a

b

+4

23

52

36

25

40

+1

5,3

120

6

5,3

7,3

16

31

68

42

32

30

16

77

9,5

74

+1

145

M20x1,5

60

±0,1

30

±0,1

0,3

0,3

M=1,2Nm

a Travel without operation:

actuator is in the guide slot, however a
function is not triggered.

b Switching operation completed:

actuator must be inserted to this point
to ensure reliable switching. The
actuator must be withdrawn at least to
point a for switching off.

inserted 100

Fig. 10: Dimension drawing NZ2VZ-5... with plug connector SR6

Figure 9: Dimension drawing NZ1VZ-...VSH with cable entry

a Travel without operation:

actuator is in the guide slot, however a
function is not triggered.

b Switching operation completed:

actuator must be inserted to this point
to ensure reliable switching. The
actuator must be withdrawn at least to
point a for switching off.

Pg 11

ma

x

.

Inserted

Inserted

b

a

0,3

+4

23

52

36

25

31

40

+1

Ш5,3

68

6

Ш5,3

7,3

42

32

30

16

77

74

+1

9,5

145

10

19

30

±0,1

60

±0,1

(F

Zh

=

F

max

) = 1500 N

1.3