EUCHNER CIS3A-Mini User Manual
Page 14

EUCHNER
Identsystem
CIS3A-Mini
084727-01-02/03
Subject to technical modification
Page 14 / 22
Byte
No.
Description
ASCII
C o n t e n t s
hex
decimal
0
Number of telegram bytes
08 ... 7B
8 ... 123
1
2
Command
identification
R
L
52
4C
82
76
3
Read/write head address *)
01
1
4
5
Start address of
user data
00
00 ... 73
0
0 ... 115
6
Number of bytes of
user data
01 ... 74
1 ... 116
7 ... 122 User data
ASCII or hex resp. BCD (code-transparent
)
Figure 5: Response telegram "read data carrier read/write" (telegram core)
Byte
No.
Description
ASCII
C o n t e n t s
hex
Decimal
0
Number of telegram bytes
07
7
1
2
Command
identification
R
F
52
46
82
70
3
Read/write head address
01
1
4
5
Padding data
00
00
0
0
6
Status number
**)
Figure 6: Response telegram "Read data carrier read/write (status)" (telegram core)
**) Status number
02
hex
: Data carrier not in active range
(more status numbers see chapter 8)