2 example, how to read a data carrier read-only, 6 command overview – EUCHNER CIS3A-Mini User Manual
Page 17

EUCHNER
Identsystem
CIS3A-Mini
084727-01-02/03
Subject to technical modification
Page 17 / 22
5.2 Example, how to read a data carrier read-only
The DIP switch of the evaluation unit has to be set to data carrier read-only prior to power on
(see chapter 2.4.1).
Data carrier no. 1 in active range:
Command telegram to read the data carrier read-only:
07
T
L
01
00
00
05
Response telegram:
12
R
L
01
00
00
05
X1
X2
X3
X4
X5
(X1 - X5 = data)
Data carrier no. 2 in active range:
Command telegram to read the data carrier read-only:
07
T
L
01
00
00
05
Response telegram:
12
R
L
01
00
00
05
X1
X2
X3
X4
X5
(X1 - X5 = data)
And so on...
6 Command overview
Description
Command telegram
Response telegram
Program data-carrier
(number of telegram bytes)
TP
(read/write head address)
(start address)
(number of bytes user data)
(user data)
(number of telegram bytes)
RF
(read/write head address)
(status no.)
Read data-carrier
(number of telegram bytes)
TL
(read/write head address)
(start address)
(number of bytes user data)
(number of telegram bytes)
RL
(read/write head address)
(start address)
(number of bytes user data)
(user data)
or
(number of telegram bytes)
RF
(read/write head address)
(status no.)