7 status messages – EUCHNER CIS3A-Mini User Manual
Page 18

EUCHNER
Identsystem
CIS3A-Mini
084727-01-02/03
Subject to technical modification
Page 18 / 22
7 Status messages
00
hex
:
No error
02
hex
:
Data carrier not in active range
03
hex
:
Read operation aborted
or
Parity bit error for data carrier read-only
04
hex
:
Error while programming or while check-reading the data carrier
05
hex
:
Write operation aborted.
(Data carrier moved out of active range during write operation)
06
hex
:
Write operation aborted.
Start address or number of bytes is not a multiple of the block size "4"
07
hex
:
Data carrier is out of active range (in TG mode only)
16
hex
:
Data length larger than 16 bytes
18
hex
:
Read attempt if EKS is set on data carrier read-only and data carrier read/write
is inserted
1D
hex
:
Read operation of a data carrier read-only with a set “number of bytes user
data” more than 5 bytes, or the start address of user data is
¹ byte 0
4X
hex
:
General error.
Try once again to read or write the data carrier
42
hex
:
Error during programming data carrier read/write.
Data carrier in read range but not in write range