7 maintenance and care, 8 repair, 9 accessories – Festo DGC-K-18 … -80 User Manual

Page 4: 10 trouble-shooting, 11 technical data

Advertising
background image

7

Maintenance and care

• Clean the belt system if required with a soft cloth.
• Avoid cleaning agents which will damage the belt system, which is made of PU.

Excessive rubbing or the use of grease-solvent cleaning agents (e.g. soap suds)
will damage the grease layer.

8

Repair

• Recommendation: Send the product to our repair service.

This will ensure that special attention is given to the necessary fine tuning and
testing.

• Information about spare parts and accessories:

(

www.festo.com/spareparts).

9

Accessories

Note

• Please select the corresponding accessories from our catalogue:

(

www.festo.com/catalogue/DGC-K).

10

Trouble-shooting

Malfunction

Possible cause

Remedy

Uneven movement of
the slide

One-way flow control valve not
installed correctly

If possible reduce the exhaust
(not the supply air)

Malfunctions in
position sensing

Ferritic parts in the vicinity of the
proximity sensor

Use parts consisting of
non-magnetic materials or
observe minimum distances
(

5.3. Installation, electric)

Heavy leakage

Linear actuator integrated in a
distorted manner

Fasten the linear actuator to a flat
base.

Seal worn

Replace worn parts:
– yourself with wearing parts kit
– send product to Festo for

repairs

Sealing band pressed/sucked in

When the linear actuator is
unpressurized:
loosen the tubing connection and
move the slide by hand through
the entire stroke twice (if
necessary, move fixed stops into
the end position)

Avoid low pressure in the piston
chamber (e.g. only move the
unpressurised slide slowly)

Linear actuator does
not achieve the
desired speed

Air volume not sufficient

– Increase connection

cross-section

– Connect volumes in series

High friction or counteracting
force

Observe limits

Fig. 17

11

Technical data

Size

18

25

32

40

50

63

80

Pneumatic connection

M5

G

Á

G

¼

G

Å

Mode of operation

Double-acting

Mounting position

Any

Operating medium

Compressed air to ISO 8573-1:2010 [7:–:–]

Notes regarding operating/
control medium

Lubricated operation possible (required during subsequent
operation)

Operating pressure

[bar]

2 … 8

1.5 … 8

Ambient temperature

[°C]

–10 … +60

Theoretical force at 6 bar [N]

153

295

483

754

1178

1870

3016

Speeds (min … max)

[m/s]

0.05 … 2

0.04 … 2

0.03 … 2

Cushioning length, PPV

[mm]

16

18

20

30

30

30

83

Cushioning

PPV

Pneumatic cushioning, adjustable at both ends

Max. impact energy

Diagrams in the catalogue

Materials

Profile tube, slide

Anodised aluminium

End cap

Aluminium

Piston

Aluminium, POM

Aluminium

Piston seal, cushioning seal,
sealing band

PU

Wiper seal, band reverser

POM

Cover strip

Steel

PU

Vapour disc

Nitrile rubber

Fig. 18

Permissible force and torque loading

Size

18

25

32

40

50

63

80

GK

Fz

max

[N]

120

330

480

800

1200

1600

2500

Mx

max

[Nm]

0.8

1.2

1.9

3.8

6

5.7

32

My

max

[Nm]

11

20

40

60

120

150

400

Mz

max

[Nm]

1

3

5

8

15

24

100

GV

Fz

max

[N]

120

330

480

800

1200

1600

Mx

max

[Nm]

1.6

2.4

3.8

7.6

12

11.4

My

max

[Nm]

22

40

80

120

240

300

Mz

max

[Nm]

2

6

10

16

30

48

0, 4

× Fz

Fz

max

+ Mx

Mx

max

+

My

My

max

+ 0, 2 × Mz

Mz

max

≤ 1

Formulas for combined loads:

Fz

Fz

max

≤ 1

Mz

Mz

max

≤ 1

Fig. 19

Advertising