SUBSTRATE PREPARATION
Defects in the substrate surface must be reported and documented
to the Building Owner’s Representative for assessment. The roofing
contractor shall not proceed with the roof system installation until
the defects in the substrate have been corrected.

Recover or Retrofit Roofing Applications: The project
specifier shall identify damaged or wet insulation areas. The insulation
as indicated shall be cut out and removed from the roof area. The
removed insulation shall be replaced with new insulation of the proper
size to fill the space (flush with existing surface ±1/4”) and obtain a
relatively smooth surface acceptable for the installation of the new
roof system.

FLEX TPO PLUS
MECHANICALLY ATTACHED ROOF MEMBRANE

INSTALLATION GUIDE

This guide is intended to be a point of reference in assisting the Flex
Authorized Applicator. The installer should always refer to the project
specifications for details and application requirements for each unique
roof system installation.

Loading the roof. Follow all OSHA procedures for safety.