SPECIFICATIONS: STEP-UP HOT PLATES

32.0”

[814mm]

27.2”

[691mm]

4.0”

[102mm]

14.5”

[368mm]

4.0”

[102mm]

4.0”

[102mm]

19.8”

[503mm]

13.0”

[330mm]

26.0”

[660mm]

5.3”

[136mm]

WIDTH

4.0”

[102mm]

1.7”

[43mm]

1.7”
[43mm]

7.6”
[192mm]

GAS INLET w/REGULATOR

For use with Natural or Propane gas only.
Gas input ratings shown for installations up to
2000 ft., (610m), above sea level. Please specify
altitudes over 2000 ft. and gas type when ordering.

Garland/U.S. Range products are not approved or authorized
for home or residential use, but are intended for commercial
applications only.
Garland/U.S. Range will not provide service,
warranty, maintenance or support of any kind other than in
commercial applications.

* Please add 7” (178mm) in overall depth

with attachment condiment rail option

.

Part # 4531352 Rev 2 (09/09/13)

Model #

Width

In (mm)

Height

(w/std legs)

Depth

In (mm)

Total Input (BTU)

Shipping

Information

NAT

PRO

Lbs/Kg

Cu Ft

UTOG24-SU4

23-5/8 (600)

19-13/16

(503)

32 (814)

120,000

104,000

135/61

8

UTOG36-SU6

35-7/16 (900)

180,000

156,000

191/87

25

UTOG48-SU8

47-1/4 (1200)

240,000

208,000

247--/112

33

SUPPLY OPERATING PRESSURE

MANIFOLD OPERATING

PRESSURE

CLEARANCES

NATURAL GAS

PROPANE

NATURAL GAS

PROPANE

INSTALLATION TO

COMBUSTIBLE

"WC

MBar

"WC

Mbar

"WC

MBar

"WC

Mbar

Sides

Rear

7

17.5

11

27.5

4.5

11

10

24.5

7” (178mm)

6” (152mm)