Specifications: radiant char-broilers – Garland US RANGE UT SERIES HEAVY DUTY GAS COUNTER EQUIPMENT User Manual

Page 7

Advertising
background image

Page 7

SPECIFICATIONS: RADIANT CHAR-BROILERS

Garland/U.S. Range products are not approved or authorized for home or residential use, but are intended for commercial applications
only. Garland/U.S. Range will not provide service, warranty, maintenance or support of any kind other than in commercial applications.

32.1”

[814mm]

4.0”

[102mm]

4.0”

[102mm]

2.4”

[62mm]

TROUGH

DEPTH

1.4” [35mm] HANDLE DEPTH MAX

15.9”

[404mm]

13.0”

[330mm]

21.2”

[538mm]

GRATE DEPTH

5.5°

HIGH GRATE

POSITION

1.4°

LOW GRATE POSITION

26.0”

[660mm]

5.3”

[136mm]

WIDTH

4.0”

102mm]

1.7”

[43mm]

1.7”
[43mm]

7.6”
[192mm]

STRAIGHT (STD) OR 3/4" N.P.T.

FLUSH REAR GAS INLET w/REGULATOR

3.3” (84mm) DIVIDER ON

UTBG48-AR48 and UTBG60-AR60

adjustable broilers.

* Please add 7” (178mm) in overall depth with
attachment condiment rail option.

GAS CONNECTION OPTIONS FOR MODEL UTBG72-NR72

STRAIGHT (STD) OR NEARLY FLUSH 1” N.P.T REAR GAS INLET

w/REGULATOR.

13.0”

[330mm]

21.2”

[538mm]

GRATE DEPTH

5.5°

GRATE ANGLE

26.0”

[660mm]

NON-ADJUSTABLE GRATE

ADJUSTABLE GRATE

For use with Natural or
Propane gas only. Gas input
ratings shown for
installations up to 2000 ft.
(610m), above sea level.
Please specify altitudes over
2000 ft. and gas type when
ordering.

Part # 4531352 Rev 2 (09/09/13)

Model #

Width

In (mm)

Height

(w/std legs)

Depth

In (mm)

Total

Input (BTU)

Shipping Information

Lbs/Kg

Cu Ft

With Adjustable Grates

UTBG24-AR24

23-5/8 (600)

13 (330)

32 (814)

72,000

283/129

19

UTBG36-AR36

35-7/16 (900)

108,000

391/178

26

UTBG48-AR48

47-1/4 (1200)

144,000

514/283

34

UTBG60-AR60

59-1/16 (1500)

180,000

635/288

41

With Non-Adjustable Grates

UTBG24-NR24

23-5/8 (600)

13 (330)

32 (814)

72,000

283/129

18

UTBG36-NR36

35-7/16 (900)

108,000

391/178

25

UTBG48-NR48

47-1/4 (1200)

144,000

514/283

33

UTBG60-NR60

59-1/16 (1500)

180,000

635/288

40

UTBG72-NR72

70 7/8(1800)

216,000

690/313

47

SUPPLY OPERATING PRESSURE

MANIFOLD OPERATING PRESSURE

INSTALLATION CLEARANCES

NATURAL GAS

PROPANE

NATURAL GAS

PROPANE

CLEARANCE: 0”

FOR INSTALLATION IN

NON-COMBUSTIBLE

SURROUNDINGS ONLY

"WC

MBar

"WC

Mbar

"WC

MBar

"WC

Mbar

7

17.5

11

27.5

4.5

11

10

24.5

Advertising