TROUBLESHOOTING continued

Malfunction With Error Code

Number of Flashing
Signals (Code)

Possible Cause

Action To Take By Operator Or Operating
Personnel

E03
- . . . - . . .

Overheated heat sink

Let unit cool down
Check air fi lter and air fl ow

Air-cooling system obstructed

Verify that air inlet and air outlet are not
obstructed with objects
Clean air fi lter

E04
- . . . . - . . . .

Overheated cooking zone

Let unit cool down
Check air fi lter and air fl ow

E06
- . . . . . . - . . . . . .

Overheated electronic

Let unit cool down
Check air fi lter and air fl ow

Ambient temperature too high (the cooling
system is not able to keep the cooker in normal
operating conditions 1)

Verify that no hot air is sucked in by the fan.
Reduce the ambient temperature. The air inlet
temperature must be lower than 104°F/40°C

E07
- . . . . . . . - . . . . . . .

Empty cooking sensing element activated

Reset empty cooking protection by switching
the unit off

E08
- . . . . . . . . - . . . . . . . .

Ambient temperature beyond operating range

Make sure that the operating conditions
(especially the ambient temperature) are kept

Error on sensing element

Contact service agent

Order of error message: The indicator lamp lights up for an interval of 0.6 sec. The number of the following short fl ashes has to be
counted and informs about the kind of error corresponding to the above mentioned code system.

The code will repeat until the error is cancelled.

1

The cooling-system (fan) starts to operate when the ambient temperature in the control area exceeds 131°F/55°C. At heat
temperatures higher than 158°F /70°C the controller automatically reduces the power to keep the unit in normal operating
conditions. The cooker runs in a non continuous mode. This mode can be heard.