Baracoda 2 User Manual

Page 18

Advertising
background image

BaracodaPencil 2 – Communication Protocol v1.3

- 18 -

Data Capture

for Workforce

in Motion

2.3.5.

2.3.5.

2.3.5.

2.3.5.

Capture

Capture

Capture

Capture

messages

messages

messages

messages

Code ID

0xE0-0xE1

Description

Get Capture Version

Payload

None

Response

“Capture Version String” or {0} if not applicable

Code ID

0xE2-0xE3

Description

Get Mode

Payload

None

Response

1 byte:

{0 = trigger, , 2 = disabled}

Code ID

0xE4-0xE5

Description

Set Mode

Payload

1 byte OR

{0 = trigger, 2 = disabled}

Response

1 byte:

{(Bit 0: Success)}

Code ID

0xE6-0xE7

Description

Get Data Format

Payload

None

Response

1 byte:

{(Bit 2:Timestamp)

(Bit 1: Capture Prefix)

(Bit 0: Capture Suffix)}

Code ID

0xE8-0xE9

Description

Set Data Format

Payload

1 byte:

{(Bit 7 = 0: Timestamp config select, =1: Timestamp config deselect)

(Bit 6 = 0: Capture Prefix config select, =1: Capture Prefix config deselect)

(Bit 5 = 0: Capture Suffix config select, =1: Capture Suffix config deselect)

(Bit 2:Timestamp)

(Bit 1: Capture Prefix)

(Bit 0: Capture Suffix) }

Response

1 byte:

{(Bit 0:Success)}

Code ID

0xEA-0xEB

Description

Get Capture Prefix

Payload

None

Response

1-33 bytes:

{ Capture Prefix length}

Advertising