Baracoda 2 User Manual

Page 37

Advertising
background image

BaracodaPencil 2 – Communication Protocol v1.3

- 37 -

Data Capture

for Workforce

in Motion

Command

Set page scan timeout

Header

0x24

Length

00 04

Payload

[Page Interval (MSB) | Page Interval (LSB) | Page Window (MSB) |

Page Window (LSB)]

(default 0x320, 0xb0)

Response

0x24 00 01 01 if done

0x24 00 01 00 if not

Remark

Page Scan TimeOuts are used by the Module to answer to Connect

Inquiries. So, if you set both values to 0, the Module will not be

Connectable.

Command

Get page scan timeout

Header

0x25

Length

00 00

Payload

Response

0x25 00 04 [Page Interval (MSB) | Page Interval (LSB) | Page

Window (MSB) | Page Window (LSB)]

Remark

Page Scan Interval and Page Scan Window are in number of

Bluetooth slots) (1 slot = 0.625 ms)

Typical values are:

Full power:

Inquiry Interval = 0x400

Inquiry Window = 0x200

Page Scan Interval = 0x400

PageScan Window = 0x200

Low power:

Inquiry Interval = 0x320

Inquiry Window = 0x80

Page Scan Interval = 0x320

PageScan Window = 0x80

Here is how these values change the consumption of the Module:

Page Scan and Inquiry Scan Interval

Inquiry Scan

Window

Page Scan

Window

Advertising