All measurement channels which have been rezeroed are designated by a
blinking measurement unit for safety reasons (see screenshot).

Caution!
A high pressure may still be present in a measurement channel featuring
a blinking unit of measurement even though the pressure reading
shows 0 bar.
When removing a sensor or other system components make sure the
system has been depressurized first. Failure to do this may pose a

hazard to life and limb.

Setting the Unit of
Measurement

The HMG 510 automatically
recognizes the unit of
measurement of the connected
HSI sensors. If you want to
display the measured value using
another unit of measurement, you
can set this via the Mode key (see

Menu Structure and Navigation of

the HMG 510

starting on page

14). The HMG 510 automatically
converts the measured value into
the new unit of measurement.