Technical Specifications

Sensor inputs

The HMG 510 features two analog inputs with automatic sensor detection at
2 input jacks (channel A and B).
Only HSI sensors (pressure, temperature or flow rate transmitters) and
SMART sensors (moisture, temperature and flow rate sensors) can be
connected.

Channel A and B:

Automatic sensor recognition for HSI and SMART sensors; automatic
setting of the measurement range and unit of measurement

Measured value differential for channel A - B

Measurement accuracy of the input channels:

≤ + 0.1% of the measurement range

Sampling rate:

0.1 ms

Measurement & display:

Current measured value

Min/max values

Measured value differential

Change of the unit of measurement

Dimensions and weight:

Measurements:

100 x 170 x 40 mm

Weight: 410

g

Operating/ambient conditions:

Operating temperature:

5 – 60°C

Storage temperature: - 40 – 70°C

Relative humidity:

0 – 70 %

Operating time using 9 V battery (2 sensors):

ca. 10 hours

Standards with Which the HMG 510 Complies

EMC: EN

61326-1+A1+A2

Safety: EN

61010

Protection rating: IP 54