Specifications – INFICON TGF10 Tracer Gas Filler User Manual

Page 9

Advertising
background image

EN

INFICON – User’s manual TGF10 7

1.5. Specifications

Connections:

4 ea. ISO G1/4”

Manometer:

- 1 to + 9 bar

Supplies:

Tracer Gas:

5% Hydrogen in 95% Nitrogen 5% H2 / 95% N2

Tracer Gas Pressure:

0 – 900 kPa

(0 – 9 bar, 0-130 PSI)

Compressed air supply:

400 – 800 kPa (4 – 8 bar, 58-116 PSI)

Compressed Air

Filtered to 40 mm

Capacity:

Evacuation:

70 std l / min free flow

Ultimate vacuum:

- 0.85 bar (-12,3 PSI)

Evacuation time:

0.7 s / l to - 0.5 bar (-7,2 PSI)

1.6 s / l to - 0.7 bar (-10,2 PSI)

3.0 s / l to - 0.8 bar (-11,6 PSI)

Filling:

600 std l / min free flow

Typically 1.0 s / l

Dimensions:

Weight:

4,7 kg

Dementions:

100 x 275 x 205 mm