INSTRUCTION SHEET

Hydrostik Hydrogen Fuel Cylinder

Installation Instructions

PN 074-626-P1A

3 of 7

WARNING

Do not use an open flame to test for leaks!

1

Connect the hydrogen fill station to the hydrogen supply tank with the fill station
3-way valve in the OFF position, pointing towards the user (

Figure 2

).

Figure 2 Connecting hydrogen fill station to hydrogen supply tank, OFF position

2

Tighten the hydrogen fill station fitting counter-clockwise onto the hydrogen supply
tank using an open-ended wrench. Do not over tighten.

3

Rotate the hydrogen fill station output valve to the FILL position, pointing toward the
hydrogen supply tank (

Figure 3

).

Figure 3 Output valve fill position

FILL position

hydrogen supply tank

Pointing toward the