INSTRUCTION SHEET

Hydrostik Hydrogen Fuel Cylinder

Installation Instructions

PN 074-626-P1A

4 of 7

4

Attach the Hydrostik adapter assembly to the hydrogen fill station by firmly pushing
the adapter assembly up onto the hydrogen fill station until a click is heard. Gently
pull down on the Hydrostik adapter assembly to ensure it is properly seated.

5

Rotate the Hydrostik adapter valve to the OPEN, or vertical position as shown
(

Figure 4

).

Figure 4 Hydrostik adapter valve OPEN position

6

Open the valve on the hydrogen supply tank at least one full turn.

7

Let Hydrostik fill with hydrogen for one hour.

CAUTION

Hydrostik will become warm during the filling process. When
Hydrostik is full, it will cool down to ambient temperature.

NOTE: A partially filled Hydrostik will take less time to fill.

8

When the filling cycle is complete, close the valve on the hydrogen supply tank.

9

Rotate the hydrogen fill station output valve to VENT position
(

Figure 5

), pointing away from the hydrogen supply tank.

Figure 5 Hydrogen fill station VENT position

OPEN

VENT position

hydrogen supply tank

Pointing away from the