Instruction sheet hydrostik hydrogen fuel cylinder – INFICON Hydrostik Hydrogen Fuel Cylinder Installation User Manual
Page 4
INSTRUCTION SHEET
Hydrostik Hydrogen Fuel Cylinder
PN 074-626-P1A
4 of 7
4
Attach the Hydrostik adapter assembly to the hydrogen fill station by firmly pushing
the adapter assembly up onto the hydrogen fill station until a click is heard. Gently
pull down on the Hydrostik adapter assembly to ensure it is properly seated.
5
Rotate the Hydrostik adapter valve to the OPEN, or vertical position as shown
(
).
Figure 4 Hydrostik adapter valve OPEN position
6
Open the valve on the hydrogen supply tank at least one full turn.
7
Let Hydrostik fill with hydrogen for one hour.
CAUTION
Hydrostik will become warm during the filling process. When
Hydrostik is full, it will cool down to ambient temperature.
NOTE: A partially filled Hydrostik will take less time to fill.
8
When the filling cycle is complete, close the valve on the hydrogen supply tank.
9
Rotate the hydrogen fill station output valve to VENT position
(
), pointing away from the hydrogen supply tank.
Figure 5 Hydrogen fill station VENT position
OPEN
VENT position
hydrogen supply tank
Pointing away from the