1.5.5 Parts and Options Overview (Single Sensor)

Cool Drawer Single Sensor . . . . . . . CDS-XXXXX (See

Figure 1-4

)

Figure 1-4 Cool Drawer single sensor configurations

1.5.6 Single Sensor Drawings

The following single sensor outline drawings provide dimensions and other
relevant data necessary for planning equipment configurations.

Figure 1-5

. . . . . . . . . . . . . . . . . . . . . Cool Drawer Sensors with 2.54 cm (1 in.) bolt

and O-ring compression fittings

Figure 1-6

. . . . . . . . . . . . . . . . . . . . . Cool Drawer sensors welded to CF 40

Figure 1-7

. . . . . . . . . . . . . . . . . . . . . Standard Cool Drawer sensor length with

shutter

Figure 1-8

. . . . . . . . . . . . . . . . . . . . . Right Angle Cool Drawer sensor length with

shutter

A

B

3
4

0
1

7

8

F

Type of Sensor

(crystals sold separately)

Standard Cool Drawer

(water lines parallel to crystal face)

Right angle Cool Drawer

(water lines perpendicular to

crystal face)

Shutter Assembly

None

Standard shutter

Length of Sensor –

SEE NOTE 1

Length – 10.2 to 66 cm

(4 to 26 in.)

Feedthrough Connection

Sensor welded to feedthrough
SEE NOTE 3

Feedthrough equipped with
Ultra-Torr

®

compression fit-

tings (allows for adjustable
sensor length). Not available
with CF40 feedthrough and
shutter combination.

Feedthrough –
SEE NOTES 2 and 5

1 in. bolt

CF40

C D S –

NOTE 1:
Orders for a WELDED sensor/feedthrough combination cannot
be accepted without a completed sensor length specification
form (provided by INFICON). Once a welded sensor order is
confirmed, it cannot be canceled.

NOTE 2:
Feedthrough configuration varies depending on options selected
(type of feedthrough, and connection). Example: CDS-A1F47
and -B1F47 use a two-piece hybrid feedthrough design due to
dimensional limits of a standard CF40.

NOTE 3:
Sensor lengths are measured from center of the crystal to the
vacuum side (sealing surface) of the feedthrough (see length
specification form).

NOTE 4:
For sensors ordered without a weld connection (option “8”),
tubes are made to a length of approximately 76.2 cm (30 in.)
for standard sensors and approximately 66 cm (26 in.) for
right angle sensors.

Note 5:
Cool Drawer sensors are not available without a feedthrough.