Spare Parts

When ordering spare parts, always indicate:
• all information on the product nameplate
• description and ordering number according to the spare

parts list

Sensor

for gauge

Ordering number

350-060, 350-080
350-062, 350-082
350-061, 350-081
350-064, 350-084
350-065, 350-085
350-063, 350-083
350-066, 350-086
350-067, 350-087
350-068, 350-088
350-200

350-920
350-922
350-921
350-924
350-926
350-923
350-925
350-927
350-928
350 930

350-140
350-142
350-141
350-144
350-145
350-143
350-146
350-147
350-148
350-300

350-900
350-902
350-901
350-904
350-906
350-903
350-905
350-907
350-908
350-940




Returning the Product

WARNING

WARNING: forwarding contaminated products
Contaminated products (e.g. radioactive, toxic,
caustic or microbiological hazard) can be detri-
mental to health and environment.
Products returned to INFICON should preferably
be free of harmful substances. Adhere to the
forwarding regulations of all involved countries
and forwarding companies and enclose a duly
completed declaration of contamination.

Products that are not clearly declared as "free of harmful sub-
stances" are decontaminated at the expense of the customer.
Products not accompanied by a duly completed declaration of
contamination are returned to the sender at his own expense.



Disposal

DANGER

DANGER: contaminated parts
Contaminated parts can be detrimental to health
and environment.
Before beginning to work, find out whether any
parts are contaminated. Adhere to the relevant
regulations and take the necessary precautions
when handling contaminated parts.

N

WARNING

WARNING: substances detrimental to the en-
vironment
Products or parts thereof (mechanical and elec-
tric components, operating fluids etc.) can be
detrimental to the environment.
Dispose of such substances in accordance with
the relevant local regulations.

Separating the components

After disassembling the product, separate its components
according to the following criteria:

• Contaminated components

Contaminated components (radioactive, toxic, caustic, or
biological hazard etc.) must be decontaminated in accor-
dance with the relevant national regulations, separated
according to their materials, and disposed of.

• Other components

Such components must be separated according to their
materials and recycled.

Declaration of Contamination

Legally binding declaration:

We hereby declare that the information on this form is
complete and accurate and that we will assume any further
costs that may arise. The contaminated product will be dis-
patched in accordance with the applicable regulations.

Organization/company
Address

Post code, place

Phone

Fax

Email

Name
Company stamp

Date and legally binding signature

Copies: Original

for

addressee

1 copy for accompanying documents

1 copy for file of sender

Operating fluid(s) used

(Must

be

drained

before

shipping.)

The service, repair, and/or disposal of vacuum equipment and com-
ponents will only be carried out if a correctly completed declaration
has been submitted. Non-completion will result in delay.
This declaration may only be completed (in block letters) and signed
by authorized and qualified staff.

Reason for return

Description

of

product

Type
Part

number

Serial

number

no yes

Used in copper process

Seal product in plastic
bag and mark it with a
corresponding label.

This form can be downloaded from our website.

The product is free
of any substances
which are damaging
to health.

yes

Process related contamination of product:

toxic

no 1) yes

corrosive

no 1) yes

biological hazard

no

yes 2)

explosive

no

yes 2)

radioactive

no

yes 2)

other harmful substances no 1) yes

1) or not containing any
amount

of

hazardous

residues that exceed the
permissible exposure limits

2) Products thus
contaminated
will

not

be

accepted

with-

out

written

evidence

of

decontami

-

nation.

Precautions associated with
substance

Action if human
contact

Trade/product name
manufacturer

Chemical name
(or symbol)

Harmful substances, gases and/or

by-products

Please list all substances, gases, and by-products
which the product may have come into contact with:


EC Declaration of Conformity

We, INFICON, hereby declare that the equip-
ment mentioned below complies with the pro-
visions of the Directive relating to electro-
magnetic compatibility 2004/108/EC.


Products

Pirani Standard Gauge

PSG500/-S, PSG502-S,
PSG510-S, PSG512-S

Standards

Harmonized and international/national standards and specifi-
cations:
• EN 61000-6-2:2005

(EMC: generic emission standard)

• EN 61000-6-3:2007

(EMC: generic immunity standard)

• EN 61010-1:2001

(Safety requirements for electrical equip-

ment for measurement, control and laboratory use)

• EN 61326-1:2006

(EMC requirements for electrical equip-

ment for measurement, control and laboratory use)


Manufacturer / Signatures

INFICON AG, Alte Landstrasse 6, LI-9496 Balzers

22 June 2010

22 June 2010

Dr. Urs Wälchli
Managing Director

Claudio Christoffel
Product Manager



LI–9496 Balzers
Liechtenstein
Tel +423 / 388 3111
Fax +423 / 388 3700
[email protected]

www.inficon.com

Advertising