Installation instructions, Shelf mounting instructions, Rack mounting instructions – Intelix FLX-88 v1.6.4 User Manual

Page 12: General i/o card installation

Advertising
background image

FLX-88 Installation Guide

12


Installation Instructions


Shelf Mounting Instructions


Attach the supplied rubber feet to the bottom of the FLX-88 matrix. Follow the instructions in General
I/O Card Installation
to install the I/O cards.

Rack Mounting Instructions


The FLX-88 requires two rack units (2 RU) of space. At least 2 inches of free air space is required on both
sides of the FLX-88 for proper side ventilation. Avoid mounting the FLX-88 near a power amplifier or any
other source of significant heat. It is recommended that you leave an empty rack space above and below
the FLX-88 for additional cooling.

General I/O Card Installation

1. Power off the matrix.
2. Remove the metal blank.

Advertising