FLX-88 Installation Guide

13


3. Slide the I/O card between the guide rails until it is firmly seated.

4. Secure the I/O card by tightening the thumb screws.

5. Connect the appropriate cabling to the I/O card.
6. Power on the matrix.

FLX-BI4 and FLX-BO4A Wiring


A compatible HDBaseT with control transmitter or receiver is required to pass the control signals to the
source or display devices.

To connect the FLX-BI4 to a compatible transmitter or the FLX-BO4A to a compatible receiver, a Cat 6 or
greater cable with a TIA-568B crimp termination on the RJ45 connector must be used. The Cat 6 cable
must not exceed 40 meters for 3D content. The Cat 6 cable must not exceed 70 meters for 2D content.