FLX-88 Installation Guide

Installation Instructions


Shelf Mounting Instructions


Attach the supplied rubber feet to the bottom of the FLX-88 matrix. Follow the instructions in
General I/O Card Installation to install the I/O cards.

Rack Mounting Instructions


The FLX-88 requires two rack units (2 RU) of space. At least 2 inches of free air space is required
on both sides of the FLX-88 for proper side ventilation. Avoid mounting the FLX-88 near a
power amplifier or any other source of significant heat. It is recommended that you leave an
empty rack space above and below the FLX-88 for additional cooling.

General I/O Card Installation

1. Power off the matrix.
2. Remove the metal blank.