FLX-1616 Installation Guide


1. Remove the crossover cable between the computer and the FLX-1616.

2. Restore the computer to the previous network settings.

3. Connect the computer and the matrix to the network.

4. Using Internet Explorer, enter the IP address for the matrix to access the browser

interface.


Additional Options in Web Browser

1. Serial Info – Adjusts TCP/IP specific settings, including the default port (4001).

a. Changing the baud rate settings has no effect on the RS232 port of the FLX-1616.
b. The baud rate setting must remain at 9600.

2. Change Password – Changes the password of the matrix.

3. Reset Device – Resets all changes to the default settings except for the IP address of the

matrix.

4. Restore Default – Resets all changes to the default settings including the IP address.


RS232 Connection


The RS232 control port requires a standard straight-through serial cable for operation. The
default settings for the RS232 port are:

-

9600 baud

-

8 Data Bits

-

1 Stop Bit

-

Parity = none