FLX-1616 Installation Guide

RS232 and TCP/IP Commands



RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None
TCP/IP Settings: User defined IP address, port 4001

There is either a period (.) or a semicolon (;) at the end of each command. These characters must
be present for the command to process correctly.

There are no spaces between any of the characters in the command string.

xx =

Input Number (input 2 would be 02)

yy =

Output Number (output 3 would be 03)

<CR> =

Carriage return (Hex 0D)

<LF> =

Line Feed (Hex 0A)

Routing Commands

Description

Command

Response

Route input xx to output yy

xxByy.

AV: xx->0yy<CR><LF>

Route input xx to all outputs

xxAll.

xx To All<CR><LF>

Route inputs to corresponding outputs

All#.

All Through.<CR><LF>

Route input xx to multiple outputs yy
Number of outputs is unlimited; each output
must be separated by a comma (,)

xxByy,yy.

xxVyy,yy<CR><LF>

Turn off all outputs

All$.

All Closed.<CR><LF>

Turn off specific output yy

yy$.

AV: yy Closed. <CR><LF>

Output yy routing status

Statusyy.

V: xx->0yy<CR><LF>

Routing status of all inputs.

Status.

V: xx->0yy<CR><LF>
(Repeating sequence
starting with output 1,
output 2, etc.)


Examples:

02All.

Route Video and Audio from input 2 to all outputs

04$.

Turn off Video and Audio for output 4

06B03.

Route Video and Audio from input 6 to output 3

03B02,08.

Route Video and Audio from input 3 to outputs 2 and 8

21