19
3 Installation
above the unit. The thyristor power unit has enclosure protection IP00, and so
it must be mounted in such a way that bodily contact is prevented (built-in
unit).
Incorrect use
- The unit is not suitable for installation in areas with an explosion hazard
(Ex areas).
- The installation site should be free from vibration, dust, and corrosive
media.
Ambient
conditions
- Side-by-side mounting of units is permitted
- Relative humidity
Յ 75 %, no condensation
- Ambient temperature range: 0 to 45 °C
Storage temperature range: -10 to 70 °C
3.4 Wall mounting
h Fix the aluminium mounting plate to the heatsink, using the cheese-head
screws provided.
h Fix the thyristor power unit with its mounting plate to the wall, using four
screws.
3.4.1 TYA-110/3, 025..100
V
The heatsink can become very hot in operation!