JUMO 60.3031 Surface-mounting thermostats, ATH.-SE Data Sheet User Manual

Surface-mounting thermostat, type series ath.-se, Types and approvals, Brief description

Advertising
background image

Page 1/6

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

Data Sheet 603031

2013-03-08/00309799

Surface-mounting thermostat, type series ATH.-SE

to monitor seagoing vessel equipment

ATHs-SE-70

Types and approvals

Type

Switching function

Hysteresis

Type No.

Test

ATHs-SE-2
ATHf-SE-2

TW

3%

68.262-F03-S1
68.262-F04-S1

Det Norske Veritas

Germanische Lloyd

DIN EN 14597

Bureau Veritas.

Pressure equipment directive

97/23/EC CE0036

(only ATH.-SE-20 and ATH.-SE-70)

ATHs-SE-2
ATHf-SE-2

6%

68.262-F03-S2
68.262-F04-S2

ATHs-SE-2
ATHf-SE-2

1.5%

68.262-F03-S3
68.262-F04-S3

ATHs-SE-20
ATHf-SE-20

STW (STB)

3%

68.261-F03-S1
68.261-F04-S1

ATHs-SE-20
ATHf-SE-20

6%

68.261-F03-S2
68.261-F04-S2

ATHs-SE-20
ATHf-SE-20

1.5%

68.261-F03-S3
68.261-F04-S3

ATHs-SE-70
ATHf-SE-70

STB

68.266-F03
68.266-F04

ATHf-SE-..

The declaration of conformity
can be found in the internet un-
der:
www.jumo.net

vProducts

vData sheet 603031

or
it can be sent on request.

Brief description

Thermostats are used to control and monitor thermal processes. The devices of the ATH.-SE
type series are available as temperature monitors TW, safety temperature monitors STW (STB)
and safety temperature limiters STB. In the event of a malfunction, the STB switches the mon-
itored machine line to an operational safe status.
Surface-mounting thermostats operate according to the fluid expansion principle,
a microswitch is used as an electrical switching element.

Switching function

Temperature monitor TW and safety temperature monitor STW
If the temperature exceeds the limit value set on the temperature probe, the current circuit is
opened via a snap switch. The switch is reset to its original status once the set limit value is
gone below (by the hysteresis).

Restart lock of the safety temperature limiter STB
If the temperature exceeds the limit value set on the temperature probe, the current circuit is
opened and mechanically locked.
Once the limit value is gone below by approx. ~ 10% of the temperature range, the switch can
be manually unlocked.

Use of the safety temperature monitor STW
as safety temperature limiter STB
Ensure that the switching circuit downstream of the thermostat complies to DIN EN 14597 and
VDE 0116.

Self-monitoring for the safety temperature limiter STB and
safety temperature monitor STW (STB)
If the measuring system is destroyed, i.e. if the expansion fluid escapes, the pressure in the di-
aphragm of the STB and STW (STB) drops and permanently opens the current circuit. Unlocking
is no longer possible.If the probe has cooled down to a temperature below approx. -20 °C, the
current circuit is opened, when the temperature rises above approx. -20 °C, the STB must be
unlocked manually first using the re-starting button. The STW (STB) automatically restarts.

Special features

Control and monitoring of thermal processes

Temperature monitor TW

Safety temperature monitor STW (STB)

and safety temperature limiter STB

Advertising