Technical Data

Display range (AB)

Display range in °C

Measuring range in °C

Tolerance in °C

469

-40...+40

-30...+30

1.5

643

-20...+120

-20...+120

3.0

807

0...+60

+10...+50

1.5

814

0...+100

+10...+90

1.5

818

0...+120

+20...+100

3.0

832

0...+200

+20...+180

3.0

840

0...+300

+30...+270

6.0

848

0...+400

+50...+350

6.0

854

0...+500

+50...+450

8.0

848

0...+600

+100...+500

10.0

Liquid filling

Gas filling

Measuring system

Display range (AB)

≤ 350°C

Display range (AB)

÷ 400°C

Time behavior

approx. 12 s, measured in water,

with a probe Ø of 6 mm made of Cu.

approx. 4 s, measured in oil,

with a probe Ø of 10 mm made of stainless steel.

Ambient temperature
influence effect

In % of the display range (referring to the deviation from the reference value +23°C)

on case

0.15% of the display range

per K ambient temperature change

0.05% of the display range

per K ambient temperature change

on capillary (per m)

0.03% of the display range

per K ambient temperature change

no influence

Higher ambient temperature – higher temperature display – lower switching point

Anti-kink spring

for devices with capillary on the case and the tem-

perature probe

Set point value setting

by set point controller in the front window

Display correction

on the rear

Limit value temperatures

for transport and storage -30°C...+70°C

(for display range -40...+40°C up to max. 50°C; -

30...+50°C up to max. 60°C)

Rated position

any

standard

Extra code (TZ) 650

Electric contact

Single-pole microswitch with mechanically actuate change-over contact

Type of contact

Contact rating

AC 230V, +10/-15%, 48...63Hz, cos

ϕ = 1 (0.6)

5 (1.5) A

10 (3) A

Hysteresis

approx. 1.5% of the display range

1.5 to 3% of the display range

Switching point accuracy

± 0.5% of the display range referring to the switch-off point with rising temperature

Switching reliability

To ensure a high switching reliability, we recommend a minimum voltage of

24 V and a minimum current of 100 mA

standard

Design 02 and 22

Design 10, 23 and TZ 426

Case

60 mm

Electrical connection

Screw-type termi-

nals, connection

cross section up to

2.5 mm

2

Connection cable 0.5 m

with screw-type terminals

Cover cap with cable

screw-connection, suitable

for cable Ø from 6.5 to

13 mm

Cover cap with cable

screw-connection,

suitable for cable Ø

from 8 to 10 mm

Advertising