Push-in thermocouple
with displaceable stop flange
and terminal head according to DIN 43729, form B 15
Insertion
length
EL in mm
Nominal
length
NL in mm
Diameter
D in mm
Temperature
range in °C
Type
up to February
28, 2013
1 couple
Type
up to February
28, 2013
2 couples
Type
as of March 01, 2013
Order code
Ceramic protection tube KER 710
Thermocouple NiCr-Ni "K"
420 to 475
500
6
-35 to +1000
-
90.023-F01 ●
901006/66-550-2043-6-500-668/000 ●
275 to 320
355
6
-35 to +1000
-
90.023-F02
901006/66-550-2043-6-355-668/000
170 to 215
250
6
-35 to +1000
-
90.023-F03
901006/66-550-2043-6-250-668/000
Operating medium: air
●
Available from stock.
Pos. 4
Versions only for connecting a
JUMO safetyM STB/STW Ex type 701155
Insertion
length
EL in mm
Nominal
length
NL in mm
Diameter
D in mm
Temperature
range in °C
1 couple
2 couples
Type
Order code
Ceramic protection tube KER 710
Thermocouple NiCr-Ni "K"
420 to 475
500
6
-35 to +1000
-
x
901006/66-550-2043-6-500-668/922
275 to 320
355
6
-35 to +1000
-
x
901006/66-550-2043-6-355-668/922
170 to 215
250
6
-35 to +1000
-
x
901006/66-550-2043-6-250-668/922
Operating medium: air
Pos. 4