JUMO 901210 Mineral-Insulated Thermocouple with Bare Connection Wires According to DIN 43710 and DIN EN 60584 Data Sheet User Manual

Technical data

Advertising
background image

2013-01-21/00073440

Data Sheet 901210

Page 1/11

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

Mineral-Insulated Thermocouples
According to DIN 43710
and DIN EN 60584

• For temperatures between -200 to +1200 °C
• Flexible sheath cable with vibration-resistant measuring insert
• Protection tube diameter as of 0.5 mm
• Quick response time
• Application-specific insertion length

Due to their specific features, mineral-insulated thermocouples are used in chemical plants,
power plants, pipelines, engine building, and test rigs. Inside the flexible and thin-walled
sheathed cable, the thermowires are embedded in compressed and fire-resistant magnesium
oxide.
The good thermal transfer between the sheath and the thermocouple enables short response
times (t

0.5

as of 0.15 s) and excellent measuring accuracy. The vibration-resistant construction

guarantees a long operating life. The smallest bending radius is 5 times the outer diameter. With
a diameter of 0.5 to 2.0 mm, the minimum insertion length (EL) is

50 mm; with a diameter of

3.0 to 6.0 mm the EL is

100 mm.

The thermocouples are designed to be insulated from the sheath as standard. The measuring
insert is equipped with thermocouples (elements) according to DIN EN 60584 and/or DIN
43710. Versions with two thermocouples are also possible.
Test pressure:

check for leaks at the measuring point at 40 bar (helium).

Leakage resistance:

thermocouple against sheath at room temperature and lengths < 1 m

200 M

Ω

, with lengths

1 m 200 M

Ω

× m.

Technical data

Terminal head

Form B, diecast aluminum, M20 × 1.5; IP65, ambient temperature -40 to +100 °C

Form BUZ, diecast aluminum, M20 × 1.5; IP65, ambient temperature -40 to +100 °C

Form J, diecast aluminum, M16 × 1.5; IP65, ambient temperature -40 to +100 °C

Caution: reduced ambient temperature when using transmitters

Connection

Cable ends stripped bare; alternatively available with ferrules, plug-in sleeves, or multi-pole electrical

connectors (e.g. thermal-voltage-free connector)

Compensating cable

Silicone, ambient temperature -50 to +180 °C

PTFE, ambient temperature 190 to +260 °C

Metal braiding, ambient temperature -20 to +350 °C

Process connection

Thread, stainless steel 1.4571

Protection tube

Stainless steel 1.4541, thermocouple type "L" and "J"

Inconel 2.4816 (Inconel 600), thermocouple type "K" and "N"

Adapter sleeve (end closure)

As standard, the adapter sleeve (end closure) is designed up to 120 °C; it is available up to 300 °C upon

request.

Measuring insert

Insulated construction:

1× Fe-CuNi "J", DIN EN 60584, class 2, operating temperature -200 to +800 °C

1× Fe-CuNi "L", DIN 43710, class 2, operating temperature -200 to +800 °C

1× NiCr-Ni "K", DIN EN 60584, class 2, operating temperature -200 to +1200 °C

1× NiCrSi-NiSi "N", DIN EN 60584, class 2, operating temperature -200 to +1200 °C

2× Fe-CuNi "L", DIN 43710, class 2, operating temperature -200 to +800 °C

2× NiCr-Ni "K", DIN EN 60584, class 2, operating temperature -200 to +1200 °C

2× NiCrSi-NiSi "N", DIN EN 60584, class 2, operating temperature -200 to +1200 °C

Response times

In water with 0.4 m/s / in air with 2 m/s

Ø 0.5 mm: water t

0.5

= 0.15 s, t

0.9

= 0.30 s/air t

0.5

= 3.5 s, t

0.9

= 8.0 s

Ø 1.0 mm: water t

0.5

= 0.20 s, t

0.9

= 0.60 s/air t

0.5

= 7.5 s, t

0.9

= 17.0 s

Ø 1.5 mm: water t

0.5

= 0.40 s, t

0.9

= 0.90 s/air t

0.5

= 10.0 s, t

0.9

= 25.0 s

Ø 2.0 mm: water t

0.5

= 0.80 s, t

0.9

= 2.60 s/air t

0.5

= 13.0 s, t

0.9

= 34.0 s

Ø 3.0 mm: water t

0.5

= 1.00 s, t

0.9

= 2.80 s/air t

0.5

= 22.0 s, t

0.9

= 64.0 s

Ø 4.5 mm: water t

0.5

= 2.50 s, t

0.9

= 6.50 s/air t

0.5

= 34.0 s, t

0.9

= 113.0 s

Ø 6.0 mm: water t

0.5

= 3.00 s, t

0.9

= 9.00 s/air t

0.5

= 55.0 s, t

0.9

= 170.0 s

Transmitter

Programmable transmitter, 4 to 20 mA / 20 to 4 mA output, data sheet 707010

programmable transmitter, 4 to 20 mA / 20 to 4 mA and HART

®

interface output, data sheet 707010