JUMO 901110 Push-in Thermocouples with Form A Terminal Head Data Sheet User Manual

Push-in thermocouples with terminal head form a, Technical data

Advertising
background image

2011-03-17/00314543

Data Sheet 90.1110 (90.1101)

Page 1/4

JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,

36039 Fulda, Germany

Postal address: 36035 Fulda, Germany
Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

e-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

e-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:

315-697-JUMO
1-800-554-JUMO

Fax:

315-697-5867

e-mail:

[email protected]

Internet: www.jumo.us

Push-in thermocouples
with terminal head form A

For temperatures from -200 to +1600 °C
With thermowells made of various materials
As single or double thermocouple
Available with transmitter

Push-in thermocouples are preferentially used for measuring temperatures in liquids and gases.
The application areas are, among others, in the HVAC, kiln and apparatus engineering sector.

The connection head form A is suitable for ambient temperatures up to +100 °C. The support
tube is made of steel. When using a counter flange, see data sheet 90.9750 (90.9725), the
installation point can be sealed up to 1 bar.

Sheaths made of various ceramic materials and heat resistant steels protect the measuring
insert against chemical influences and mechanical damage. The selection of a suitable sheath
material depends on the conditions on site.

Thermocouples (elements) as per DIN EN 60584 and DIN 43710, class 2, are set into the
measuring insert. Versions with two thermocouples are also possible.

Technical data

Terminal head

Form A DIN 43729, die-cast aluminum, M 20x1.5; IP54, ambient temperature -40 to +100 °C
Caution: reduced ambient temperature when using connection head transmitters, data sheets
70.7010 and 70.7060

Process connection

Sheath screw-connection G 1
Stop flange Ø 22 mm, DIN 43734
Stop flange Ø 32 mm, DIN 43734

Sheath

Steel 1.4749, Ø 22 mm, operating temperature up to +1150 °C (seamless)
Steel 1.4841, Ø 22 mm, operating temperature up to +1150 °C (seamless)
Ceramic C 610 (KER 610), Ø 15 mm, Ø 24 mm, operating temperatures up to +1300 °C
Ceramic C 799 (KER 710), Ø 15 mm, Ø 24 mm, operating temperatures up to +1600 °C

Measuring insert

Insulated structure:
1x Fe-CuNi „J“, DIN EN 60584, cl. 2, operating temperature -200 to +600 °C
1x Fe-CuNi „L“, DIN 43710, cl. 2, operating temperature -200 to +600 °C
1x NiCr-Ni „K“, DIN EN 60584, cl. 2, operating temperature -200 to +1200 °C
1x Pt10Rh-Pt „S“, DIN EN 60584, cl. 2, operating temperature 0 to 1300 °C
1x Pt30Rh-Pt6Rh „B“, DIN EN 60584, cl. 2, operating temperature 600 to 1600 °C
2x Fe-CuNi „J“, DIN EN 60584, cl. 2, operating temperature -200 to +600 °C
2x Fe-CuNi „L“, DIN 43710, cl. 2, operating temperature -200 to +600 °C
2x NiCr-Ni „K“, DIN EN 60584, cl. 2, operating temperature -200 to +1200 °C
2x Pt10Rh-Pt „S“, DIN EN 60584, cl. 2, operating temperature 0 to 1300 °C
2x Pt30Rh-Pt6Rh „B“, DIN EN 60584, cl. 2, operating temperature 600 to 1600 °C

Transmitter

Programmable transmitter, 4 to 20 mA/20 to 4 mA output, data sheet 70.7010
Wtrans B programmable head transducer with radio transmission, data sheet 70.7060
(suitable Wtrans receivers, data sheet 90.2931)

Advertising