JUMO 901020 Screw-In Thermocouples with Terminal Head Form B Data Sheet User Manual

Screw-in thermocouples with terminal head form b, Technical data

Advertising
background image

Data Sheet 90.1020 (90.1002)

Page 1/4

JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,

36039 Fulda, Germany

Postal address: 36035 Fulda, Germany
Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

e-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

e-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:

315-697-JUMO
1-800-554-JUMO

Fax:

315-697-5867

e-mail:

[email protected]

Internet: www.jumo.us

Screw-in thermocouples
with terminal head form B

For temperatures from -200 to +800 °C
Available with different thermocouples
As single or double thermocouple
Connection head form B, BUZ, BUZH, BBK
Available with transmitter

Screw-in thermocouples are preferentially used for measuring temperatures in fluids and gases.
A decisive selection criterion is the reliable sealing feature of this installation type with vacuum
and with overpressure. Application fields are found, amongst others, in heating, furnace/kiln
and process technology.
The connection head is suitable for ambient temperatures up to +100 C. The versions BUZ,
BUZH and BBK are also available in addition to the standard connection head, form B.
Sheaths made of stainless steel protect the measuring insert against chemical influences and
mechanical damage.
Thermocouples (elements) as per DIN EN 60584, class 2 and DIN 43710 are set into the
measuring insert. Versions with two thermocouples are also possible.

Technical data

Terminal head

Form B DIN 43729, die-cast aluminum, M 20x1.5; IP65, ambient temperature -40 to +100 °C
Form BUZ, die-cast aluminum, M 20x1.5; IP65, ambient temperature -40 to +100 °C
Form BUZH, die-cast aluminum, M 20x1.5; IP65, ambient temperature -40 to +100 °C
Form BBK, plastic, M 20x1.5; IP54, ambient temperature -30 to +130 °C
Caution: reduced ambient temperature range when using transmitters,
Data sheets 70.7010 and 70.7060

Extension tube

Stainless steel 1.4571, length 130 mm

Process connection

thread, stainless steel 1.4571

Sheath

Stainless steel 1.4571, diameter 9 mm

Measuring insert

Exchangeable, insulated structure:
1x Fe-CuNi „J“, DIN EN 60584, cl. 2, operating temperature -200 to +600 °C
1x Fe-CuNi „L“, DIN 43710, cl. 2, operating temperature -200 to +600 °C
1x NiCr-Ni „K“, DIN EN 60584, cl. 2, operating temperature -200 to +800 °C
2x Fe-CuNi „J“, DIN EN 60584, cl. 2, operating temperature -200 to +600 °C
2x Fe-CuNi „L“, DIN 43710, cl. 2, operating temperature -200 to +600 °C
2x NiCr-Ni „K“, DIN EN 60584, cl. 2, operating temperature -200 to +800 °C

Transmitter

Programmable transmitter, 4 to 20 mA/20 to 4 mA output, data sheet 70.7010
Wtrans B programmable head transducer with radio transmission, data sheet 70.7060
(suitable Wtrans receivers, data sheet 90.2931)

Accessories

Sheath, data sheet 90.9710 (90.9721)

2011-03-17/00314536