2012-03-02/00473251

Data sheet 902930

Page 12/25

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone: 315-697-5866

1-800-554-JUMO

Fax:

315-697-5867

E-mail:

[email protected]

Internet: www.jumo.us

Note:
The extension tube length (position 6) has a standard length of 70 mm. 120 mm are available upon request (for orders, please specify in plain text).
The extension tube length is added to the selected insertion length. To calculate the heat input, a temperature-dependent calculation basis is
provided for an extension tube length of 70 mm and 120 mm (please refer to the operating manual).

Order details:

JUMO Wtrans transmitter T03.G1 Ex insertion RTD temperature probe

(1) Basic type

902930/15

Wtrans transmitter T03.G1 Ex
Insertion RTD temperature probe
with ATEX approval
Intrinsically safe device according to EC directive 94/9/EC (ATEX)
(Ambient temperature, case: -30 to +85 °C)
Please specify the requirement for zone separation in plain text!

(2) Operating temperature in °C (protection fitting)

x

596

-30 to +260 °C

(3) Measuring insert

x

1006

1x Pt1000 in 3-wire circuit

(4) Tolerance class according to DIN EN 60751

x

2

Class A

(5) Protection tube diameter D in mm

x

4

Ø 4 mm

x

6

Ø 6 mm (zone separation possible)

x

9

Ø 9 mm (zone separation possible)

(6) Insertion length EL in mm (EL 30 to 1000 mm)

x

30

30 mm (observe extension tube length 70 mm)

x

80

80 mm (observe extension tube length 70 mm)

x

130

130 mm (observe extension tube length 70 mm)

x

...

For orders, specify in plain text (stepped down by 50 mm)

(7) Insertion tip

x

1

Flat

(8) Radio frequency

x

10

868.4 MHz (Europe)

(9) Process connection

x

000

None

x

103

Screw connection G 3/8 (zone separation possible)

x

104

Screw connection G 1/2 (zone separation possible)

x

252

Pipe screw connection G 1/4 (for protection tube diameter 6 mm only)

x

253

Pipe screw connection G 3/8 (for protection tube diameter 6 mm only)

x

254

Pipe screw connection G 1/2 (for protection tube diameter 6 mm only)

x

255

Pipe screw connection G 3/4 (for protection tube diameter 6 mm only)

x

263

Pipe screw connection M10 x 1 (for protection tube diameter 6 mm only)

x

291

Pipe screw connection 1/2-14NPT (for protection tube diameter 6 mm only)

x

662

Sheet steel flange (for protection tube diameter 6 mm only)

x

...

Different process connections upon request

(10) Extra codes

x

362

Ex protection Ex i according to EC directive 94/9/EC (ATEX)

x

778

Customer-specific transmission interval 5 s, 10 s, or 45 s, for orders,
specification in plain text (factory-set to 20 s)

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

Order code

-

-

-

-

-

-

-

-

/

362

, ...

1

Order example

902930/15

-

596

-

1006

-

2

-

6

-

80

-

1

-

10

-

000

/

362

1

List extra codes in sequence, separated by commas.