JUMO 902434 HEATtemp Push-In RTD Temperature Probe for Heat and Cold Meter with Terminal Head for Thermowells, Type PL Data Sheet User Manual

Technical data

Advertising
background image

Data sheet 902434

Page 1/5

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

• For temperatures between 0 and 180 °C
• Approval for heat meters as replaceable temperature probes;

MID and domestic approvals

• Fulfills the requirements of DIN EN 1434, AGFW 202, and FW211
• Paired and calibrated according to the German calibration regulations
• Production certified according to module D of MID (CE and metrology identification

marking)

• Adapted accessories for installation (data sheet 902440)
• Approval for cold meter

Heat and cold meter RTD temperature probes are installed to measure temperatures in closed
pipeline systems. Thanks to insertion into thermowells with matching tolerance, emptying the
system for the regular replacement at the end of the certification period is no longer necessary.
The temperature probes are approved according to the EU directive 2004/22/EC (MID) as well
as according to the German calibration regulations (domestic approval). The temperature probes
are available in paired and calibrated versions. The officially recognized testing agency for heat
KF2 is available for this. Moreover, the production is certified according to module D of MID, and
the temperature probes are also available with the CE and metrology identification marking.

Technical data

Terminal head

Form J or B, aluminum diecast,
M16 × 1.5 or M24 × 1.5, IP65,
ambient temperature -20 to +100 °C

Process connection

Push-in RTD temperature probe
for thermowells (immersion sleeves)

Protection tube

Stainless steel, Ø 6 mm with matching tolerance
for thermowell

Measuring insert

Platinum temperature sensor according to DIN
EN 60751
Nominal value: Pt100, Pt500, Pt1000; class B
Connection: two-wire or four-wire circuit

Temperature

0 to 180 °C

Temperature difference

3 to 180 K

Minimum immersion depth

25 mm

Insertion length

85 to 400 mm

Admissible rated pressure PN

40 bar (with thermowell)

Response behavior

t

0.5

10 s (installed in thermowell)

Thermoelectric voltage

5 µV

Environmental conditions

Climatic 0 to 70 °C
Protection type IP65
Electromagnetic E1
Mechanical M3
Environment class C

Accessories

Thermowells, data sheet 902440

2014-04-01/00530101

Push-in RTD Temperature Probe

for Heat and Cold Meters

with Terminal Head for Thermowells (Type PL)