JUMO 902424 HEATtemp Screw-In RTD Temperature Probe for Heat and Cold Meter with Terminal Head for Direct Installation, Type DL Data Sheet User Manual

Technical data

Advertising
background image

Data sheet 902424

Page 1/6

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866

1-800-554-5866

Fax:

315-437-5860

E-mail:

[email protected]

Internet: www.jumousa.com

• For temperatures between 0 and 180 °C
• Approval for heat meters as replaceable temperature probes;

MID and domestic approvals

• Fulfills requirements of DIN EN 1434, AGFW 202, and FW211
• Paired and calibrated according to the German calibration regulations
• Production certified according to module D of MID (CE and metrology identification

marking)

• Approval for cold meter

Heat and cold meter RTD temperature probes are used for temperature measurement in closed
pipeline systems. Direct mounting without an additional thermowell is recommended to achieve
optimum thermal coupling to the measurement medium in the heating system.
The temperature probes are approved according to the EU directive 2004/22/EC (MID) as well
as according to the German calibration regulations (domestic approval).
The temperature probes are available in paired and calibrated versions. The officially recognized
testing agency for heat KF2 is available for this. Moreover, the production is certified according
to module D of MID, and the temperature probes are also available with the CE and metrology
identification marking.

Technical data

Terminal head

Form J or B, aluminum diecast,
M16 × 1.5 or M24 × 1.5, IP65,
ambient temperature -20 to +100 °C

Process connection

Thread G 1/2, stainless steel

Protection tube

Stainless steel, Ø 6 mm
or Ø 8 mm stepped down to Ø 6 mm

Measuring insert

Platinum temperature sensor according to DIN
EN 60751
Nominal value: Pt100, Pt500, Pt1000; class B
Connection: two-wire or four-wire circuit

Temperature

0 to 180 °C

Temperature difference

3 to 180 K

Minimum immersion depth

25 mm

Insertion length

85 to 280 mm

Admissible rated pressure PN

25 bar

Maximum flow velocity

2 m/s (water)

Thermoelectric voltage

5 µV

Response behavior

t

0.5

5 s

Environmental conditions

Climate -25 to +70 °C
Protection type IP65
Electromagnetic E1
Mechanical M3
Environment class C

2014-03-18/00386325