JUMO 706021 LOGOLINE 500d Line Recorder Data Sheet User Manual

Overview of functions, Applications, Approvals/marks of conformity

Advertising
background image

JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,

36039 Fulda, Germany

Postal address: 36035 Fulda, Germany
Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

e-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

e-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:

315-697-JUMO
1-800-554-JUMO

Fax:

315-697-5867

e-mail:

[email protected]

Internet: www.jumo.us

Page 1/11

Data Sheet 706021 (706000)

2010-06-21/00324162

Overview of functions

1, 2 or 3 analog inputs
(configurable and electrically
isolated)

Thermocouple, RTD temperature probe,
Resistance transmitter, Potentiometer,
Voltage, Current

8 logic inputs
(available as an option)

for floating contacts or PLC level
Functions:
- External texts

- Binary-linked text

- External stop

- External speed

- Event counter

- External scaling

- External report

Outputs
(available as an option)

- Interface for 8 relay outputs

- Supply for 2-wire transmitter

Recording

- Measurement traces

- Text printing

Setup interface

for configuration and parameter setting

RS422/RS485 interface
(available as an option)

Data transfer from and to the recorder

Applications

k Failure and fault analysis

k Compliance with official regulations

k Reports for users and customers

k Monitoring of processes

k Optimization of procedures

Pen recorder with text printing
and LED dot-matrix display

Brief description

The pen recorder offers up to three measurement inputs for recording the measurements,
which are isolated from each other by optocouplers. The measurements can be read by
pointers against scales, or are shown on the display. Channel 1 can be used to output text
in addition to the measurement trace.
All channels are zeroed using Hall sensors.
The watchdog monitors the pen recorder function and triggers a restart in the event of a
fault. The configuration data are stored permanently in EEPROM. On a power failure, the
real-time clock is buffered by the recorders.
The standard current and voltage signals as well as thermocouples, RTD temperature
probes, resistance transmitters and potentiometers can be connected to the recorder. The
necessary linerarization is performed automatically.
Optional expansions are available. Eight logic inputs are available for additional operating
functions. In most cases, a math and logic module permits the recorder to be individually
adapted to complex measurement tasks. An external relay module ER8 for rail mounting
supplements the pen recorder by eight switching outputs. A 2-wire transmitter can be op-
erated from an isolated supply.

d

Type 706021/…

Approvals/marks of conformity

(see Technical data)

Advertising